Your browser doesn't support javascript.
loading
Efficient EEG motion artifact elimination framework for ambulatory epileptic seizure detection application.
Y, Murali Krishna; P, Vinay Kumar.
Afiliação
  • Y MK; Department of Electronics and Communication Engineering, JNTUK, Kakinada, 533003, Andhra Pradesh, India.
  • P VK; Department of Electronics and Communication Engineering, UCEK, JNTUK, Kakinada, 533003, Andhra Pradesh, India.
Biomed Phys Eng Express ; 10(3)2024 Mar 12.
Article em En | MEDLINE | ID: mdl-38437724
ABSTRACT
Motion artifacts are a pervasive challenge in EEG ambulatory monitoring, often obscuring critical neurological signals and impeding accurate seizure detection. In this study, we propose a new approach of outlier based grouping of two level Singular Spectrum Analysis (SSA) decomposition combined with Relative Total Variation (RTV) filter for the effective removal of motion-induced noise from ambulatory EEG data. A two-stage SSA method was employed to decompose single-channel EEG signal, which had been interfered with, into various fre quency bands. The affected sub-band signal was then subjected to an RTV filter to estimate the artifact signal. Subtracting this estimated artifact signal from the contaminated sub-band signal yielded the filtered sub-band signal. Subse quently, the filtered sub-band signal was reintegrated with the other decomposed components from noise-free bands, culminating in the generation of the ultimate denoised EEG signal. Based on the comprehensive set of simulation results, it can be deduced that the algorithm described in the paper outperforms existing methods. It demonstrates superior metrics evaluation in terms of ΔSNR,η,MAE, andPSNRwhen compared to these alternatives. Our framework sig- nificantly enhances the quality of EEG data by successfully eliminating motion artifacts while preserving crucial brainwave information. To evaluate the prac tical impact of this noise reduction technique, we assess its performance in the context of seizure detection. The results reveal a substantial improvement in the accuracy and reliability of seizure detection algorithms when applied to EEG data preprocessed with proposed method.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Artefatos / Eletroencefalografia Limite: Humans Idioma: En Revista: Biomed Phys Eng Express Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Artefatos / Eletroencefalografia Limite: Humans Idioma: En Revista: Biomed Phys Eng Express Ano de publicação: 2024 Tipo de documento: Article