Your browser doesn't support javascript.
loading
In vitro assessment of cytotoxicity of spent fluid catalytic cracking refinery catalysts on cell lines and identification of critical toxic metals.
Wang, Yue-Jie; Sheng, Zhi-Guo; Li, Jun; Zhao, Zhen-Feng; Li, Ling-Ling; Shen, Chen.
Afiliação
  • Wang YJ; State Key Laboratory of Chemical Safety, SINOPEC Research Institute of Safety Engineering Co., Ltd., Qingdao 266100, Shandong, PR China.
  • Sheng ZG; State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, and University of Chinese Academy of Sciences, Chinese Academy of Sciences, Beijing 100085, PR China; University of Chinese Academy of Sciences, Beijing 100049, PR China.
  • Li J; State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, and University of Chinese Academy of Sciences, Chinese Academy of Sciences, Beijing 100085, PR China; University of Chinese Academy of Sciences, Beijing 100049, PR China.
  • Zhao ZF; State Key Laboratory of Chemical Safety, SINOPEC Research Institute of Safety Engineering Co., Ltd., Qingdao 266100, Shandong, PR China; SINOPEC National Petrochemical Project Risk Assessment Technical Center Co. Ltd., Qingdao 266100, Shandong, PR China.
  • Li LL; State Key Laboratory of Chemical Safety, SINOPEC Research Institute of Safety Engineering Co., Ltd., Qingdao 266100, Shandong, PR China.
  • Shen C; State Key Laboratory of Chemical Safety, SINOPEC Research Institute of Safety Engineering Co., Ltd., Qingdao 266100, Shandong, PR China. Electronic address: shenc.qday@sinopec.com.
Toxicol In Vitro ; 97: 105807, 2024 May.
Article em En | MEDLINE | ID: mdl-38458499
ABSTRACT
The Purpose of the present study was to quantify the responses of ten cell lines (HeLa, HepG2, HEK293, MDA-MB-231, A498, A549, A357, 3 T3, BALB-C3 T3, and NIH-3 T3) to spent fluid catalytic cracking catalysts (SFCCCs) from different petroleum refineries, and relate these responses to metal concentrations of SFCCC leachates (SFCCCLs). Cytotoxicity of SFCCCs were significantly different depending on cell lines. A357 and 3 T3 cell were the most sensitive, and A498 and HeLa cells were the least sensitive. HEK293 cells showed the least fluctuation in toxic response to different SFCCCLs among all cells. Cytotoxic IC50 values of SFCCCs to 7 kinds of cells were the most correlated with vanadium (V) concentration in SFCCCLs. V is the most critical toxic factor of SFCCC. Glutathione synthesis was induced in HepG2 cells exposed to higher concentrations of SFCCCLs. SFCCCLs with low concentration of V can induce the decrease of GSH/GSSG ratio in HepG2 cells, suggesting that high concentration of V inhibits the detoxification of glutathione.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Glutationa / Metais Limite: Humans Idioma: En Revista: Toxicol In Vitro Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Glutationa / Metais Limite: Humans Idioma: En Revista: Toxicol In Vitro Ano de publicação: 2024 Tipo de documento: Article