Impact of Flexible Circuit Bonding and System Integration on Energy Resolution of Cross-Strip CZT Detectors.
Enlow, Emily; Diba, Milad; Clayton, James; Harris, Brian; Abbaszadeh, Shiva.
Afiliação
  • Enlow E; Department of Electrical and Computer Engineering, University of California Santa Cruz, Santa Cruz, CA 95064 USA.
  • Diba M; Department of Electrical and Computer Engineering, University of California Santa Cruz, Santa Cruz, CA 95064 USA.
  • Clayton J; Polymer Assembly Technology Inc., Rockford, MI 49341 USA.
  • Harris B; Kromek, Zelienople, PA 16063 USA.
  • Abbaszadeh S; Department of Electrical and Computer Engineering, University of California Santa Cruz, Santa Cruz, CA 95064 USA.
IEEE Trans Radiat Plasma Med Sci ; 7(6): 580-586, 2023 Jul.
Article em En | MEDLINE | ID: mdl-38468608
ABSTRACT
Cadmium zinc telluride (CZT) detectors enable high spatial resolution and high detection efficiency and are utilized for many gamma-ray and X-ray spectroscopy applications. In this article, we describe a stable bonding process and report on the characterization of cross-strip CZT detectors before and after bonding to flexible circuit. The bonding process utilizes gold stud bonding and polymer epoxy technique to bond the flexible circuits to two CZT crystals and form a detector module in an anode-cathode-cathode-anode (ACCA) configuration. The readout electronics is optimized in terms of shaper setting and steering electrode voltage. The average full-width half maximum (FWHM) energy resolution at 662 keV of 110 CZT crystals tested individually was 3.5% ± 0.59% and 4.75% ± 0.48% prebonded and post-bonded, respectively. No depth correction was performed in this study. The average FWHM energy resolution at 662 keV of the scaled-up system with 80 CZT crystals was 4.40% ± 0.53%, indicating the scaled-up readout electronics and stacking of the modules does not deteriorate performance. The proper shielding and grounding of the scaled-up system slightly improved the system-wide performance. The FWHM energy resolution at 511 keV of the scaled-up system was 5.85% ± 0.73%.