Comparison of Oxygen Delivery Devices in Postoperative Patients with Hypoxemia: An Open-labeled Randomized Controlled Study.
Mishra, Susri; Kothari, Nikhil; Sharma, Ankur; Goyal, Shilpa; Rathod, Darshna; Meshram, Tanvi; Bhatia, Pradeep.
Afiliação
  • Mishra S; Department of Anesthesiology and Critical Care, All India Institute of Medical Sciences, Jodhpur, Rajasthan, India.
  • Kothari N; Department of Anesthesiology and Critical Care, All India Institute of Medical Sciences, Jodhpur, Rajasthan, India.
  • Sharma A; Department of Trauma and Emergency (Anesthesiology and Critical Care), All India Institute of Medical Sciences, Jodhpur, Rajasthan, India.
  • Goyal S; Department of Anesthesiology and Critical Care, All India Institute of Medical Sciences, Jodhpur, Rajasthan, India.
  • Rathod D; Department of Anesthesiology and Critical Care, All India Institute of Medical Sciences, Jodhpur, Rajasthan, India.
  • Meshram T; Department of Anesthesiology and Critical Care, All India Institute of Medical Sciences, Jodhpur, Rajasthan, India.
  • Bhatia P; Department of Anesthesiology and Critical Care, All India Institute of Medical Sciences, Jodhpur, Rajasthan, India.
Indian J Crit Care Med ; 28(3): 294-298, 2024 Mar.
Article em En | MEDLINE | ID: mdl-38477006
ABSTRACT

Background:

Acute hypoxemic respiratory failure is among the more commonly occurring complications in postoperative patients. Supplemental oxygen and addressing the primary etiology form the basis of its treatment. Materials and

methods:

We conducted an open-labeled randomized control trial with 90 adult patients and compared three oxygen delivery vehicles (ODV), i.e., noninvasive ventilation (NIV), high-flow nasal cannula (HFNC), and venturi mask (VM) in postoperative hypoxemic patients. The primary outcome variable was a change in the P/F ratio after 2 hours of use of ODV.

Results:

It was observed that the change in P/F ratio after 2 hours was similar in all three ODV groups (p = 0.274). The mean values of the post-ODV P/F ratio were comparable with the pre-ODV P/F ratio in all three modalities. The P/F ratio after HFNC was 358.08 ± 117.95; after NIV was 357.60 ± 220.67; and after VM was 355.47 ± 101.90 (p = 0.997).

Conclusion:

Among HFNC, NIV, and VM, none of the devices proved superior to the other for use in postoperative hypoxemia. How to cite this article Mishra S, Kothari N, Sharma A, Goyal S, Rathod D, Meshram T, et al. Comparison of Oxygen Delivery Devices in Postoperative Patients with Hypoxemia An Open-labeled Randomized Controlled Study. Indian J Crit Care Med 2024;28(3)294-298.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Indian J Crit Care Med Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Indian J Crit Care Med Ano de publicação: 2024 Tipo de documento: Article