Study of thermal effects induced by the high-frequency probing laser in nonlinear opto-acoustic frequency-mixing technique.
Yuan, Ling; Ni, Chen-Yin; Zhang, Yi-Fei; Zhang, Hong-Chao; Shen, Zhong-Hua.
Afiliação
  • Yuan L; School of Science, Nanjing University of Science and Technology, 200 Xiaolingwei Street, Xuanwu District, Nanjing, 210094, PR China.
  • Ni CY; School of Science, Nanjing University of Science and Technology, 200 Xiaolingwei Street, Xuanwu District, Nanjing, 210094, PR China.
  • Zhang YF; School of Science, Nanjing University of Science and Technology, 200 Xiaolingwei Street, Xuanwu District, Nanjing, 210094, PR China.
  • Zhang HC; School of Science, Nanjing University of Science and Technology, 200 Xiaolingwei Street, Xuanwu District, Nanjing, 210094, PR China.
  • Shen ZH; School of Science, Nanjing University of Science and Technology, 200 Xiaolingwei Street, Xuanwu District, Nanjing, 210094, PR China. Electronic address: shenzh@njust.edu.cn.
Ultrasonics ; 139: 107288, 2024 Apr.
Article em En | MEDLINE | ID: mdl-38513438
ABSTRACT
Photo-thermal modulation-based nonlinear opto-acoustic frequency-mixing technique is an effective method for detecting micro-cracks. When using this technique for micro-crack detection, the selection of laser source parameters is particularly crucial. Compared to traditional piezo-transducer-based mixing techniques, the characteristic of using a laser as the detection source is the presence of thermal effects. The thermal effect caused by laser irradiation on the sample surface can not only generate acoustic waves but also affect the crack state, thus influencing nonlinear signals. In this paper, an experimental setup using photo-thermal modulation-based nonlinear opto-acoustic frequency-mixing technique has been set up to investigate the thermal effects of the probe laser source. In addition, a corresponding physical model has been established to discuss the physical mechanisms revealed by the experimental results. This study provides a basis for selecting appropriate probe source parameters and scanning positions of laser sources when detecting micro-cracks using the photo-thermal modulation-based nonlinear opto-acoustic frequency-mixing technique.