Your browser doesn't support javascript.
loading
A convenient spectrophotometric test for screening skin-sensitizing chemicals using reactivity with glutathione in chemico.
Cha, Dong Ho; Kim, Geon Ho; Nepal, Rahul U; Nepal, Mahesh R; Jeong, Tae Cheon.
Afiliação
  • Cha DH; College of Pharmacy, Yeungnam University, 280 Daehak-Ro, Gyeongsan, 38541 Republic of Korea.
  • Kim GH; College of Pharmacy, Yeungnam University, 280 Daehak-Ro, Gyeongsan, 38541 Republic of Korea.
  • Nepal RU; College of Pharmacy, Yeungnam University, 280 Daehak-Ro, Gyeongsan, 38541 Republic of Korea.
  • Nepal MR; College of Pharmacy, Yeungnam University, 280 Daehak-Ro, Gyeongsan, 38541 Republic of Korea.
  • Jeong TC; College of Pharmacy, Yeungnam University, 280 Daehak-Ro, Gyeongsan, 38541 Republic of Korea.
Toxicol Res ; 40(2): 203-213, 2024 Apr.
Article em En | MEDLINE | ID: mdl-38525138
ABSTRACT
To initiate skin sensitization, haptens react with endogenous proteins. During this process, skin sensitizers react with small endogenous molecules containing thiol or amino groups. In this study, a simple spectrophotometric method to identify skin sensitizers in chemico was developed using the reactivity of glutathione (GSH) with test chemicals in a 96-well plate. To quantitate the remaining GSH following the reaction with a skin sensitizer, 5,5'-dithiobis-(2-nitrobenzoic acid) (DTNB) was employed. The optimized experimental conditions included the pH- and time-dependent stability of GSH, stability of derivatized products of GSH with optimal concentration and incubation time of DTNB, incubation time of GSH with the test chemicals, and molar ratios of GSH to the test chemicals. With the optimized conditions with both acetonitrile and DMSO as vehicles and incubation of GSH with test chemicals in 110 and 115 ratios for 24 h at 4 °C, 23 skin sensitizers and 23 non-sensitizers, based on the local lymph node assay, were tested to determine the predictive capacity of individual conditions. The best result showed a predictive capacity of 95.2% sensitivity, 91.3% specificity, and 93.2% accuracy, with 93.2% consistency in three trials, when 5.8% depletion was used as a cut-off value in 110 of GSHtest chemicals in DMSO. It would be an economic and useful screening tool for determining the skin sensitization potential of small molecules, because the present method employs simple endogenous GSH as an electron donor for sensitizers with a spectrophotometric detection system in 96-well plates, and because the method requires neither experimental animals nor cell cultures. Supplementary Information The online version contains supplementary material available at 10.1007/s43188-023-00218-9.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Toxicol Res Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Toxicol Res Ano de publicação: 2024 Tipo de documento: Article