Your browser doesn't support javascript.
loading
Crown adjustment and chairside efficiency of single-unit restorations fabricated from immediate and staged impressions using a digital workflow for posterior implants.
Ren, Shuxin; Jiang, Xi; Lin, Ye; Di, Ping.
Afiliação
  • Ren S; Department of Oral Implantology, Peking University School and Hospital of Stomatology, Beijing, China.
  • Jiang X; Department of Oral Implantology, Peking University School and Hospital of Stomatology, Beijing, China.
  • Lin Y; Department of Oral Implantology, Peking University School and Hospital of Stomatology, Beijing, China.
  • Di P; Department of Oral Implantology, Peking University School and Hospital of Stomatology, Beijing, China.
J Prosthodont ; 33(7): 637-644, 2024 Aug.
Article em En | MEDLINE | ID: mdl-38526488
ABSTRACT

PURPOSE:

This is a clinical study to compare immediate and staged impression methods in a complete digital workflow for single-unit implants in the posterior area. MATERIALS AND

METHODS:

Sixty patients requiring single-unit implant crowns were enrolled. Forty patients were assigned to the test group, immediate digital impression after implant surgery with crown delivery 4 months later. The remaining 20 patients were assigned to the control group, staged digital impressions 4 months after implant surgery, and crown delivery 1 month later. Both workflows involved free-model CAD-CAM crown fabrications. The crowns were scanned before and after clinical adjustment using an intraoral scanner (TRIOS Color; 3Shape). Two 3D digital models were trimmed and superimposed to evaluate the dimensional changes using Geomagic Control software. Chairside times for the entire workflow were recorded. Kruskal-Wallis was performed to compare crown adjustments between two groups, while One-way ANOVA was used to compare chairside time durations between the test and control groups.

RESULTS:

All crowns were delivered without refabrication. The average maximum occlusion adjustment of crowns was -353.2 ± 207.1 µm in the test group and -212.7 ± 150.5 µm in the control group (p = 0.02). The average area of occlusal adjustment, measured as an area of deviation larger than 100 µm, was 14.8 ± 15.3 and 8.4 ± 8.1 mm2 in the test and control groups, respectively (p = 0.056). There were no significant differences in the mesial and distal contact adjustment amounts, or the maximum deviations of the proximal area, between the two groups. The mean chair-side time was 50.25 ± 13.48 and 51.20 ± 5.34 min in the test and control groups, respectively (p = 0.763).

CONCLUSIONS:

The immediate impression method in the digital workflow for single-unit implants required more occlusal adjustments of crowns but showed similar chairside times compared to the staged impression method.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnica de Moldagem Odontológica / Desenho Assistido por Computador / Implantes Dentários para Um Único Dente / Coroas / Fluxo de Trabalho Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: J Prosthodont Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnica de Moldagem Odontológica / Desenho Assistido por Computador / Implantes Dentários para Um Único Dente / Coroas / Fluxo de Trabalho Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: J Prosthodont Ano de publicação: 2024 Tipo de documento: Article