A Comparative Biomechanical Study of Alternative Medial Collateral Ligament Reconstruction Techniques.
Am J Sports Med
; 52(6): 1505-1513, 2024 May.
Article
em En
| MEDLINE
| ID: mdl-38551132
ABSTRACT
BACKGROUND:
There is little evidence of the biomechanical performance of medial collateral ligament (MCL) reconstructions for restoring stability to the MCL-deficient knee regarding valgus, external rotation (ER), and anteromedial rotatory instability (AMRI).HYPOTHESIS:
A short isometric reconstruction will better restore stability than a longer superficial MCL (sMCL) reconstruction, and an additional deep MCL (dMCL) graft will better control ER and AMRI than single-strand reconstructions. STUDYDESIGN:
Controlled laboratory study.METHODS:
Nine cadaveric human knees were tested in a kinematics rig that allowed tibial loading while the knee was flexed-extended 0° to 100°. Optical markers were placed on the femur and tibia and displacements were measured using a stereo camera system. The knee was tested intact, and then after MCL (sMCL + dMCL) transection, and loaded in anterior tibial translation (ATT), ER, varus-valgus, and combined ATT + ER (AMRI loading). Five different isometric MCL reconstructions were tested isolated long sMCL, a short construct, each with and without dMCL addition, and isolated dMCL reconstruction, using an 8 mm-wide synthetic graft.RESULTS:
MCL deficiency caused an increase in ER of 4° at 0° of flexion (P = .271) up to 14° at 100° of flexion (P = .002), and valgus laxity increased by 5° to 8° between 0° and 100° of flexion (P < .024 at 0°-90°). ATT did not increase significantly in isolated MCL deficiency (P > .999). All 5 reconstructions restored native stability across the arc of flexion apart from the isolated long sMCL, which demonstrated residual ER instability (P≤ .047 vs other reconstructions).CONCLUSION:
All tested techniques apart from the isolated long sMCL graft are satisfactory in the context of restoring the valgus, ER, and AMRI stability to the MCL-deficient knee in a cadaveric model. CLINICAL RELEVANCE Contemporary MCL reconstruction techniques fail to control ER and therefore AMRI as they use a long sMCL graft and do not address the dMCL. This study compares 5 MCL reconstruction techniques. Both long and short isometric constructs other than the long sMCL achieved native stability in valgus and ER/AMRI. Double-strand reconstructions (sMCL + dMCL) tended to provide more stability. This study shows which reconstructions demonstrate the best biomechanical performance, informs surgical reconstruction techniques for AMRI, and questions the efficacy of current popular techniques.Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Cadáver
/
Ligamento Colateral Médio do Joelho
/
Instabilidade Articular
Limite:
Aged
/
Female
/
Humans
/
Male
/
Middle aged
Idioma:
En
Revista:
Am J Sports Med
Ano de publicação:
2024
Tipo de documento:
Article