Your browser doesn't support javascript.
loading
Low concentration of peroxymonosulfate coupled with visible light triggers oxygen reactive species generation over constructed Bi25FeO40/BiOCl Z-scheme heterojunction for various tetracycline antibiotics removal.
Zhang, Rui; Dong, Jintao; Li, Lina; Zhao, Junze; Ji, Mengxia; Wang, Bin; Xia, Jiexiang; Li, Huaming.
Afiliação
  • Zhang R; School of Chemistry and Chemical Engineering, Institute for Energy Research, Jiangsu University, 301 Xuefu Road, Zhenjiang 212013, China.
  • Dong J; School of Chemistry and Chemical Engineering, Institute for Energy Research, Jiangsu University, 301 Xuefu Road, Zhenjiang 212013, China.
  • Li L; School of Chemistry and Chemical Engineering, Institute for Energy Research, Jiangsu University, 301 Xuefu Road, Zhenjiang 212013, China.
  • Zhao J; School of Chemistry and Chemical Engineering, Institute for Energy Research, Jiangsu University, 301 Xuefu Road, Zhenjiang 212013, China.
  • Ji M; School of Chemistry and Chemical Engineering, Institute for Energy Research, Jiangsu University, 301 Xuefu Road, Zhenjiang 212013, China.
  • Wang B; School of Chemistry and Chemical Engineering, Institute for Energy Research, Jiangsu University, 301 Xuefu Road, Zhenjiang 212013, China.
  • Xia J; School of Chemistry and Chemical Engineering, Institute for Energy Research, Jiangsu University, 301 Xuefu Road, Zhenjiang 212013, China. Electronic address: xjx@ujs.edu.cn.
  • Li H; School of Chemistry and Chemical Engineering, Institute for Energy Research, Jiangsu University, 301 Xuefu Road, Zhenjiang 212013, China. Electronic address: lhm@ujs.edu.cn.
J Colloid Interface Sci ; 665: 825-837, 2024 Jul.
Article em En | MEDLINE | ID: mdl-38564946
ABSTRACT
Photocatalytic peroxymonosulfate (PMS) oxidation systems demonstrate significant potential and promising prospects through the interconnection of photocatalytic and PMS oxidation for simultaneously achieving efficient pollutant removal and reduction of PMS dosage, which prevents resource wastage and secondary pollution. In this study, a Z-scheme Bi25FeO40/BiOCl (BOFC) heterojunction was constructed to carry out the photocatalytic PMS oxidation process for tetracyclines (TCs) pollutants at low PMS concentrations (0.08 mM). The photocatalytic PMS oxidation rate of Bi25FeO40/BiOCl composites for tetracycline hydrochloride (TCH), chlortetracycline (CTC), oxytetracycline (OTC) and doxycycline (DXC) reaches 86.6%, 83.6%, 86.7%, and 88.0% within 120 min. Simultaneously, the BOFC/PMS system under visible light (Vis) equally displayed the practical application prospects for the solo and mixed simulated TCs antibiotics wastewater. Based on the electron spin resonance (ESR) and X-ray photoelectron spectroscopy (XPS) valence band spectrum, a Z-scheme electron migration pathway was proposed to elucidate the mechanism underlying the performance enhancement of BOFC composites. Bi25FeO40 in BOFC composites can serve as active site for activating PMS by the formation of Fe3+/Fe2+ cycle. Toxicity estimation software tool (T.E.S.T.) and mung beans planting experiment demonstrates that BOFC/PMS/Vis system can reduce toxicity of TCs wastewater. Therefore, BOFC/PMS/Vis system achieves efficient examination in different water environments and efficient utilization of PMS, which displays a scientific reference for achieving environmentally-friendly and resource-saving handling processes.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Contexto em Saúde: 2_ODS3 Base de dados: MEDLINE Assunto principal: Peróxidos / Poluentes Ambientais / Águas Residuárias Idioma: En Revista: J Colloid Interface Sci Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Contexto em Saúde: 2_ODS3 Base de dados: MEDLINE Assunto principal: Peróxidos / Poluentes Ambientais / Águas Residuárias Idioma: En Revista: J Colloid Interface Sci Ano de publicação: 2024 Tipo de documento: Article