Your browser doesn't support javascript.
loading
Extraocular muscle electromyographic recordings for intraoperative monitoring of cranial nerves III, IV, and VI: a single-center experience with intraorbital electrodes.
Oishi, Tatsuya; Van Gompel, Jamie J; Link, Michael J; Peris Celda, Maria; Daniels, David J; Morris, Jonathan M; Hoffman, Ernest M.
Afiliação
  • Oishi T; Departments of1Neurology.
  • Van Gompel JJ; 2Neurosurgery, and.
  • Link MJ; 2Neurosurgery, and.
  • Peris Celda M; 2Neurosurgery, and.
  • Daniels DJ; 2Neurosurgery, and.
  • Morris JM; 3Radiology, Mayo Clinic, Rochester, Minnesota.
  • Hoffman EM; Departments of1Neurology.
J Neurosurg ; : 1-12, 2024 Apr 05.
Article em En | MEDLINE | ID: mdl-38579353
ABSTRACT

OBJECTIVE:

The objective of this study was to describe the quantitative features of intraoperative electromyographic recordings obtained from cranial nerve III, IV, and VI neuromonitoring using 25-mm intraorbital electrodes, in the larger context of demonstrating the practicality of this technique during neurosurgical cases.

METHODS:

A 25-mm-long shaft-insulated intraorbital needle electrode is routinely used at the authors' institution for extraocular muscle (EOM) electromyographic monitoring of the inferior rectus, superior oblique, and/or lateral rectus muscles when their function is at risk. Cases monitored between January 1, 2021, and December 31, 2022, were reviewed for patient demographics, tumor location and pathology, EOMs monitored, pre- and postoperative examination, and complications from electrode placement. Compound muscle action potentials on triggered electromyography, as well as neurotonic discharges on free-run electromyography, were described quantitatively.

RESULTS:

There were 141 cases in 139 patients reviewed during the 24-month time span, with 278 EOMs monitored (inferior rectus/superior oblique/lateral rectus muscles 68/68/142). Triggered electromyography yielded biphasic or triphasic compound muscle action potentials from EOMs with a mean onset latency of 1.51 msec (range 0.94-3.22 msec), mean maximal peak-to-trough amplitude of 1073.93 µV (range 76.75-7796.29 µV), and high specificity for the channel in nearly all cases. Neurotonic discharges were recorded in 30 of the 278 EOMs (with all 3 muscles represented) and associated with a greater incidence of new or worsened ophthalmoparesis (OR 4.62, 95% CI 1.3-16.4). There were 2 cases of small periorbital ecchymosis attributed to needle placement; additionally, 1 case of needle-related intraorbital hematoma occurred after the review period.

CONCLUSIONS:

The 25-mm shaft-insulated intraorbital electrode facilitates robust and consistent electromyographic recordings of EOMs that are advantageous over existing techniques. Combined with the relative ease of needle placement and low rate of complications, the technique is practical for neuromonitoring during craniotomies.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Neurosurg Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Neurosurg Ano de publicação: 2024 Tipo de documento: Article