Your browser doesn't support javascript.
loading
Silver Nanoparticles In Situ Enhanced Electrochemiluminescence of the Porphyrin Organic Matrix for Highly Sensitive and Rapid Monitoring of Tetracycline Residues.
Han, Qian; Shi, Xueran; Kang, Kai; Cao, Yingbo; Cong, Lin; Wang, Jing.
Afiliação
  • Han Q; School of Pharmacy, Key Laboratory of Innovative Drug Development and Evaluation, Hebei Medical University, Shijiazhuang, Hebei 050017, China.
  • Shi X; School of Pharmacy, Key Laboratory of Innovative Drug Development and Evaluation, Hebei Medical University, Shijiazhuang, Hebei 050017, China.
  • Kang K; School of Pharmacy, Key Laboratory of Innovative Drug Development and Evaluation, Hebei Medical University, Shijiazhuang, Hebei 050017, China.
  • Cao Y; School of Pharmacy, Key Laboratory of Innovative Drug Development and Evaluation, Hebei Medical University, Shijiazhuang, Hebei 050017, China.
  • Cong L; School of Pharmacy, Key Laboratory of Innovative Drug Development and Evaluation, Hebei Medical University, Shijiazhuang, Hebei 050017, China.
  • Wang J; School of Pharmacy, Key Laboratory of Innovative Drug Development and Evaluation, Hebei Medical University, Shijiazhuang, Hebei 050017, China.
J Agric Food Chem ; 2024 Apr 11.
Article em En | MEDLINE | ID: mdl-38602881
ABSTRACT
Accurate monitoring of tetracycline (TC) residues in the environment is crucial for avoiding contaminant risk. Herein, a novel TC biosensor was facilely designed by integrating silver nanoparticles (Ag NPs) into the porphyrin metal-organic matrix (Ag@AgPOM) as a bifunctional electrochemiluminescence (ECL) probe. Different from the step-by-step synthesis of the co-reaction accelerator and ECL emitter, the co-reaction accelerators Ag NPs were in situ-grown on the surface of 5,10,15,20-tetrakis (4-carboxyphenyl) porphyrin (TCPP) via a simple one-pot approach. Symbiotic Ag NPs on Ag@AgPOM formed an intimate interface and increased the collision efficiency of the ECL reaction, achieving the ECL enhancement of TCPP. Under the optimized conditions, the ternary ECL biosensor showed a wide linear detection range toward TC with a low detection limit of 0.14 fmol L-1. Compared with the traditional HPLC and ELISA methods, satisfied analytical adaptability made this sensing strategy feasible to monitor TC in complex environmental samples.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Agric Food Chem Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Agric Food Chem Ano de publicação: 2024 Tipo de documento: Article