Your browser doesn't support javascript.
loading
Development of a reverse transcription loop-mediated isothermal amplification assay with novel quantitative pH biosensor readout method for SARS-CoV-2 detection.
Astari, Dian Ekayanti; Massi, Muhammad Nasrum; Masadah, Rina; Hardjo, Marhaen; Natzir, Rosdiana; Erlichster, Michael; Chana, Gursharan; Skafidas, Efstratios; Seraj, Zeba Islam; Elias, Sabrina M; Soraya, Gita Vita.
Afiliação
  • Astari DE; Department of Biomedicine, Graduate School Hasanuddin University, Makassar, Indonesia.
  • Massi MN; Department of Biochemistry, Faculty of Medicine, Hasanuddin University, Makassar, Indonesia.
  • Masadah R; Department of Biomedicine, Graduate School Hasanuddin University, Makassar, Indonesia.
  • Hardjo M; Department of Microbiology,Faculty of Medicine, Hasanuddin University, Makassar, Indonesia.
  • Natzir R; Department of Biomedicine, Graduate School Hasanuddin University, Makassar, Indonesia.
  • Erlichster M; Department of Pathology Anatomy, Faculty of Medicine, Hasanuddin University, Makassar, Indonesia.
  • Chana G; Department of Biomedicine, Graduate School Hasanuddin University, Makassar, Indonesia.
  • Skafidas E; Department of Biochemistry, Faculty of Medicine, Hasanuddin University, Makassar, Indonesia.
  • Seraj ZI; Department of Biomedicine, Graduate School Hasanuddin University, Makassar, Indonesia.
  • Elias SM; Department of Biochemistry, Faculty of Medicine, Hasanuddin University, Makassar, Indonesia.
  • Soraya GV; MX3 Diagnostics Inc., Melbourne, Victoria, Australia.
APMIS ; 132(7): 499-506, 2024 Jul.
Article em En | MEDLINE | ID: mdl-38659394
ABSTRACT
Reverse transcription loop-mediated isothermal amplification (RT-LAMP) is a molecular amplification method that can detect SARS-CoV-2 in a shorter time than the current gold-standard molecular diagnostic reverse transcription-polymerase chain reaction (RT-PCR). However, previously developed RT-LAMP assays have mostly relied on highly subjective visual colorimetric interpretation. In this study, an RT-LAMP assay was developed with quantitative measurement of reaction pH using a novel portable pH biosensor compared to qualitative colorimetric interpretation and gel electrophoresis, with 57 clinical COVID-19 samples used for validation of the test. The LoD of the assay is 103 copies/µL. The highest sensitivity was found in the qualitative methods (93.75%), while the highest specificity and likelihood ratio was found in the pH sensor (87.5% and 6.72). On the sensor measurement, a significant difference (p < 0.0001) was observed between the average pH of the RT-PCR (+) COVID-19 (6.15 ± 0.27), while the average pH of the RT-PCR (-) samples (6.72 ± 0.22). Correlation analysis revealed a strong correlation (r = 0.78, p < 0.0001) between the Ct values obtained from RT-PCR with the biosensor pH readout. RT-LAMP with the quantitative pH sensor readout method has the potential to be further developed as an objective molecular assay for rapid and simple detection of SARS-CoV-2.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Sensibilidade e Especificidade / Técnicas de Amplificação de Ácido Nucleico / SARS-CoV-2 / COVID-19 Limite: Humans Idioma: En Revista: APMIS Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Sensibilidade e Especificidade / Técnicas de Amplificação de Ácido Nucleico / SARS-CoV-2 / COVID-19 Limite: Humans Idioma: En Revista: APMIS Ano de publicação: 2024 Tipo de documento: Article