Your browser doesn't support javascript.
loading
Comparison of refractive outcomes obtained with two swept-source OCT-based optical biometers after cataract surgery: A study of 152 eyes.
Agard, E; Levron, A; Billant, J; Douma, I; Dot, C.
Afiliação
  • Agard E; Department of Ophthalmology, Desgenettes Military Hospital, 108, boulevard Pinel, 69003 Lyon, France. Electronic address: emilie.agard@hotmail.fr.
  • Levron A; Department of Ophthalmology, Desgenettes Military Hospital, 108, boulevard Pinel, 69003 Lyon, France.
  • Billant J; Department of Ophthalmology, Desgenettes Military Hospital, 108, boulevard Pinel, 69003 Lyon, France.
  • Douma I; Department of Ophthalmology, Desgenettes Military Hospital, 108, boulevard Pinel, 69003 Lyon, France.
  • Dot C; Department of Ophthalmology, Desgenettes Military Hospital, 108, boulevard Pinel, 69003 Lyon, France; French Military Health Service Academy, Val de Grâce, Paris, France; FEBO (Fellow of European Board of Ophthalmology), France.
J Fr Ophtalmol ; 47(6): 104186, 2024 Jun.
Article em En | MEDLINE | ID: mdl-38663226
ABSTRACT

PURPOSE:

To compare two swept-source OCT optical biometers, the Anterion® (Heidelberg Engineering GmbH, Heidelberg, Germany) and the IOLMaster 700® (Carl Zeiss Meditec AG, Jena, Germany), in the analysis of biometric data, intraocular lens (IOL) calculation and postoperative spherical equivalent predictability.

METHODS:

This was a real-life, single-center, retrospective study including 152 eyes of 81 consecutive patients referred for cataract surgery. All patients were examined with the IOLMaster 700® and the Anterion®. Biometric data (axial length [AL], anterior chamber depth [ACD], mean keratometry [Km], K1 [flat keratometry], K2 [steep keratometry] and axis, TK1 [flat total keratometry], TK2 [steep total keratometry], central pachymetry, lens thickness [LT], white-to-white distance [WTW]), IOL calculation with the SRK/T formula, and postoperative refractive outcome at 1 month were compared.

RESULTS:

All biometric measurements were significantly different between the two biometers. Correlations were excellent for AL, pachymetry, ACD, LT and keratometry measurements, and for the IOL calculation (r>0.96, intraclass correlation coefficient=1). The IOL power for emmetropia was similar between both biometers when the SRK/T formula was used (20.84±3.24D versus 20.86±3.29D, P=0.61). The mean postoperative spherical equivalent prediction error calculated using the SRK/T formula was 0.03±0.5D for the IOLMaster 700® versus 0.01±0.47D for the Anterion® (P=0.12).

CONCLUSIONS:

This study showed excellent correlation and agreement for the biometric measurements and the IOL power calculation with the SRK/T formula between both biometers.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Refração Ocular / Extração de Catarata / Biometria / Tomografia de Coerência Óptica / Lentes Intraoculares Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: J Fr Ophtalmol Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Refração Ocular / Extração de Catarata / Biometria / Tomografia de Coerência Óptica / Lentes Intraoculares Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: J Fr Ophtalmol Ano de publicação: 2024 Tipo de documento: Article