Your browser doesn't support javascript.
loading
Added Value of [18F]PSMA-1007 PET/CT and PET/MRI in Patients With Biochemically Recurrent Prostate Cancer: Impact on Detection Rates and Clinical Management.
Abrahamsen, Bendik S; Tandstad, Torgrim; Aksnessæther, Bjørg Y; Bogsrud, Trond V; Castillejo, Miguel; Hernes, Eivor; Johansen, Håkon; Keil, Thomas M I; Knudtsen, Ingerid S; Langørgen, Sverre; Selnæs, Kirsten M; Bathen, Tone F; Elschot, Mattijs.
Afiliação
  • Abrahamsen BS; Department of Circulation and Medical Imaging, Norwegian University of Science and Technology, Trondheim, Norway.
  • Tandstad T; The Cancer Clinic, St. Olavs Hospital, Trondheim University Hospital, Trondheim, Norway.
  • Aksnessæther BY; Department of Clinical and Molecular Medicine, Norwegian University of Science and Technology, Trondheim, Norway.
  • Bogsrud TV; Department of Oncology, Ålesund Hospital, Møre and Romsdal Hospital Trust, Ålesund, Norway.
  • Castillejo M; PET Imaging Centre, University Hospital of North Norway, Tromsø, Norway.
  • Hernes E; PET-Centre, Aarhus University Hospital, Aarhus, Denmark.
  • Johansen H; PET Imaging Centre, University Hospital of North Norway, Tromsø, Norway.
  • Keil TMI; Division of Radiology and Nuclear Medicine, Oslo University Hospital, Oslo, Norway.
  • Knudtsen IS; Department of Radiology and Nuclear Medicine, St. Olavs Hospital, Trondheim University Hospital, Trondheim, Norway.
  • Langørgen S; Department of Radiology and Nuclear Medicine, St. Olavs Hospital, Trondheim University Hospital, Trondheim, Norway.
  • Selnæs KM; Department of Circulation and Medical Imaging, Norwegian University of Science and Technology, Trondheim, Norway.
  • Bathen TF; Department of Radiology and Nuclear Medicine, St. Olavs Hospital, Trondheim University Hospital, Trondheim, Norway.
  • Elschot M; Department of Radiology and Nuclear Medicine, St. Olavs Hospital, Trondheim University Hospital, Trondheim, Norway.
J Magn Reson Imaging ; 2024 Apr 28.
Article em En | MEDLINE | ID: mdl-38679841
ABSTRACT

BACKGROUND:

Prostate-specific membrane antigen (PSMA) positron emission tomography (PET) can change management in a large fraction of patients with biochemically recurrent prostate cancer (BCR).

PURPOSE:

To investigate the added value of PET to MRI and CT for this patient group, and to explore whether the choice of the PET paired modality (PET/MRI vs. PET/CT) impacts detection rates and clinical management. STUDY TYPE Retrospective.

SUBJECTS:

41 patients with BCR (median age [range] 68 [55-78]). FIELD STRENGTH/SEQUENCE 3T, including T1-weighted gradient echo (GRE), T2-weighted turbo spin echo (TSE) and dynamic contrast-enhanced GRE sequences, diffusion-weighted echo-planar imaging, and a T1-weighted TSE spine sequence. In addition to MRI, [18F]PSMA-1007 PET and low-dose CT were acquired on the same day. ASSESSMENT Images were reported using a five-point Likert scale by two teams each consisting of a radiologist and a nuclear medicine physician. The radiologist performed a reading using CT and MRI data and a joint reading between radiologist and nuclear medicine physician was performed using MRI, CT, and PET from either PET/MRI or PET/CT. Findings were presented to an oncologist to create intended treatment plans. Intrareader and interreader agreement analysis was performed. STATISTICAL TESTS McNemar test, Cohen's κ, and intraclass correlation coefficients. A P-value <0.05 was considered significant.

RESULTS:

7 patients had positive findings on MRI and CT, 22 patients on joint reading with PET/CT, and 18 patients joint reading with PET/MRI. For overall positivity, interreader agreement was poor for MR and CT (κ = 0.36) and almost perfect with addition of PET (PET/CT κ = 0.85, PET/MRI κ = 0.85). The addition of PET from PET/CT and PET/MRI changed intended treatment in 20 and 18 patients, respectively. Between joint readings, intended treatment was different for eight patients. DATA

CONCLUSION:

The addition of [18F]PSMA-1007 PET/MRI or PET/CT to MRI and CT may increase detection rates, could reduce interreader variability, and may change intended treatment in half of patients with BCR. LEVEL OF EVIDENCE 3 TECHNICAL EFFICACY Stage 3.