Residual risk of Pseudomonas aeruginosa waterborne contamination in an intensive care unit despite the presence of filters at all water points-of-use.
Royer, G; Virieux-Petit, M; Aujoulat, F; Hersent, C; Baranovsky, S; Hammer-Dedet, F; Masnou, A; Marchandin, H; Corne, P; Jumas-Bilak, E; Romano-Bertrand, S.
Afiliação
  • Royer G; Hydrosciences Montpellier, IRD, CNRS, Univ Montpellier, Service de Prévention des Infections et de la Résistance, CHU Montpellier, Montpellier, France; Département de prévention, diagnostic et traitement des infections, Hôpital Henri Mondor, AP-HP, Créteil, France.
  • Virieux-Petit M; Hydrosciences Montpellier, IRD, CNRS, Univ Montpellier, Service de Prévention des Infections et de la Résistance, CHU Montpellier, Montpellier, France; Hydrosciences Montpellier, Univ Montpellier, IRD, CNRS, Montpellier, France.
  • Aujoulat F; Hydrosciences Montpellier, Univ Montpellier, IRD, CNRS, Montpellier, France.
  • Hersent C; Service de Prévention des Infections et de la Résistance, CHU Montpellier, France.
  • Baranovsky S; Service de Prévention des Infections et de la Résistance, CHU Montpellier, France.
  • Hammer-Dedet F; Hydrosciences Montpellier, Univ Montpellier, IRD, CNRS, Montpellier, France.
  • Masnou A; Hydrosciences Montpellier, Univ Montpellier, IRD, CNRS, Montpellier, France.
  • Marchandin H; Hydrosciences Montpellier, Univ Montpellier, IRD, CNRS, Montpellier, France; Service de Microbiologie et Hygiène hospitalière, CHU Nîmes, Nîmes, France.
  • Corne P; Département de Médecine Intensive et Réanimation, CHU Montpellier, Montpellier, France.
  • Jumas-Bilak E; Hydrosciences Montpellier, IRD, CNRS, Univ Montpellier, Service de Prévention des Infections et de la Résistance, CHU Montpellier, Montpellier, France.
  • Romano-Bertrand S; Hydrosciences Montpellier, IRD, CNRS, Univ Montpellier, Service de Prévention des Infections et de la Résistance, CHU Montpellier, Montpellier, France. Electronic address: sara.romano-bertrand@umontpellier.fr.
J Hosp Infect ; 149: 155-164, 2024 Jul.
Article em En | MEDLINE | ID: mdl-38705477
ABSTRACT

OBJECTIVE:

To assess the residual risk of waterborne contamination by Pseudomonas aeruginosa from a water network colonized by a single genotype [sequence type (ST) 299] despite the presence of antimicrobial filters in a medical intensive care unit (ICU).

METHODS:

During the first 19-month period since the ICU opened, contamination of the water network was assessed monthly by collecting water upstream of the filters. Downstream water was also sampled to assess the efficiency of the filters. P. aeruginosa isolates from patients were collected and compared with the waterborne ST299 P. aeruginosa by multiplex-rep polymerase chain reaction (PCR), pulsed-field gel electrophoresis (PFGE) and whole-genome sequencing. Cross-transmission events by other genotypes of P. aeruginosa were also assessed.

RESULTS:

Overall, 1.3% of 449 samples of filtered water were positive for P. aeruginosa in inoculum, varying between 1 and 104 colony-forming units/100 mL according to the tap. All P. aeruginosa hydric isolates belonged to ST299 and displayed fewer than two single nucleotide polymorphisms (SNPs). Among 278 clinical isolates from 122 patients, 10 isolates in five patients showed identical profiles to the hydric ST299 clone on both multiplex-rep PCR and PFGE, and differed by an average of fewer than five SNPs, confirming the water network reservoir as the source of contamination by P. aeruginosa for 4.09% of patients. Cross-transmission events by other genotypes of P. aeruginosa were responsible for the contamination of 1.75% of patients. DISCUSSION/

CONCLUSION:

Antimicrobial filters are not sufficient to protect patients from waterborne pathogens when the water network is highly contaminated. A microbiological survey of filtered water may be needed in units hosting patients at risk of P. aeruginosa infections, even when all water points-of-use are fitted with filters.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pseudomonas aeruginosa / Infecções por Pseudomonas / Microbiologia da Água / Eletroforese em Gel de Campo Pulsado / Genótipo / Unidades de Terapia Intensiva Limite: Humans Idioma: En Revista: J Hosp Infect / J. hosp. infect / Journal of Hospital Infection Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pseudomonas aeruginosa / Infecções por Pseudomonas / Microbiologia da Água / Eletroforese em Gel de Campo Pulsado / Genótipo / Unidades de Terapia Intensiva Limite: Humans Idioma: En Revista: J Hosp Infect / J. hosp. infect / Journal of Hospital Infection Ano de publicação: 2024 Tipo de documento: Article