Your browser doesn't support javascript.
loading
A multifunctional ionic liquid coating on 3D-Printed prostheses: Combating infection, promoting osseointegration.
Li, Zuhao; Jin, Lunqiang; Yang, Xijing; Liu, He; Qian, Shengxu; Wang, Zhonghan; Liu, Jiaqi; Wang, Jingxia; Chen, Junjun; Su, Baihai; Peng, Chaorong; Wang, Jincheng; Shi, Zhenqiang.
Afiliação
  • Li Z; School of Bioengineering, Dalian University of Technology, Dalian 116024, China.
  • Jin L; Department of Orthopaedics, Xinhua Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai 200092, China.
  • Yang X; Orthopaedic Medical Center, The Second Hospital of Jilin University, Changchun 130041, China.
  • Liu H; Department of Nephrology, West China Hospital of Sichuan University, Chengdu, 610041, China.
  • Qian S; Animal Experiment Center, West China Hospital, Sichuan University, Chengdu 610041, China.
  • Wang Z; Orthopaedic Medical Center, The Second Hospital of Jilin University, Changchun 130041, China.
  • Liu J; School of Bioengineering, Dalian University of Technology, Dalian 116024, China.
  • Wang J; Orthopaedic Medical Center, The Second Hospital of Jilin University, Changchun 130041, China.
  • Chen J; Orthopaedic Medical Center, The Second Hospital of Jilin University, Changchun 130041, China.
  • Su B; Radiation Chemistry Department, Sichuan Institute of Atomic Energy, Chengdu 610101, China.
  • Peng C; School of Bioengineering, Dalian University of Technology, Dalian 116024, China.
  • Wang J; Department of Nephrology, West China Hospital of Sichuan University, Chengdu, 610041, China.
  • Shi Z; Radiation Chemistry Department, Sichuan Institute of Atomic Energy, Chengdu 610101, China.
Mater Today Bio ; 26: 101076, 2024 Jun.
Article em En | MEDLINE | ID: mdl-38711938
ABSTRACT
Periprosthetic infection and mechanical loosening are two leading causes of implant failure in orthopedic surgery that have devastating consequences for patients both physically and financially. Hence, advanced prostheses to simultaneously prevent periprosthetic infection and promote osseointegration are highly desired to achieve long-term success in orthopedics. In this study, we proposed a multifunctional three-dimensional printed porous titanium alloy prosthesis coated with imidazolium ionic liquid. The imidazolium ionic liquid coating exhibited excellent bacterial recruitment property and near-infrared (NIR) triggered photothermal bactericidal activity, enabling the prosthesis to effectively trap bacteria in its vicinity and kill them remotely via tissue-penetrating NIR irradiation. In vivo anti-infection and osseointegration investigations in infected animal models confirmed that our antibacterial prosthesis could provide long-term and sustainable prevention against periprosthetic infection, while promoting osseointegration simultaneously. It is expected to accelerate the development of next-generation prostheses and improve patient outcomes after prosthesis implantation.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Mater Today Bio Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Mater Today Bio Ano de publicação: 2024 Tipo de documento: Article