Quantitative detection of microcystin-LR in Bellamya aeruginosa by thin-layer chromatography coupled with surface-enhanced Raman spectroscopy based on in-situ ZIF-67/Ag NPs/Au NWs composite substrate.
Jiang, Jing; Liu, Min; Xu, Dalun; Jiang, Tao; Zhang, Jinjie.
Afiliação
  • Jiang J; College of Food and Pharmaceutical Sciences, School of Physical Science and Technology, Ningbo University, Ningbo 315211, Zhejiang, PR China. Electronic address: 2111085049@nbu.edu.cn.
  • Liu M; College of Food and Pharmaceutical Sciences, School of Physical Science and Technology, Ningbo University, Ningbo 315211, Zhejiang, PR China.
  • Xu D; College of Food and Pharmaceutical Sciences, School of Physical Science and Technology, Ningbo University, Ningbo 315211, Zhejiang, PR China. Electronic address: xudalun@nbu.edu.cn.
  • Jiang T; College of Food and Pharmaceutical Sciences, School of Physical Science and Technology, Ningbo University, Ningbo 315211, Zhejiang, PR China. Electronic address: jiangtao@nbu.edu.cn.
  • Zhang J; College of Food and Pharmaceutical Sciences, School of Physical Science and Technology, Ningbo University, Ningbo 315211, Zhejiang, PR China. Electronic address: zhangjinjie@nbu.edu.cn.
Food Chem ; 452: 139481, 2024 Sep 15.
Article em En | MEDLINE | ID: mdl-38723565
ABSTRACT
As a hypertoxic natural toxin, the risk of Microcystin-leucine-arginine (MC-LR) residues in Bellamya aeruginosa deserves more attention. Herein, employing the conventional thin-layer chromatography (TLC) technology and a novel surface-enhanced Raman scattering (SERS) substrate, a TLC-SERS chip was fabricated for the purification and quantitative detection of MC-LR in complex samples. The substrate exhibited excellent SERS performance with an enhancement factor of 6.6 × 107, a low detection limit of 2.27 × 10-9 mM for MC-LR, excellent uniformity and reproducibility, as well as a wide linear range. With the application of TLC, the MC-LR was efficiently purified and the concentration was increased to >3 times. Ultimately, recovery rates fluctuated between 93.28% and 101.66% were obtained from the TLC-SERS chip. On balance, the TLC-SERS chip has a robust capacity for achieving rapid and stable quantitative detection of MC-LR, which promises to improve the efficiency of food safety monitoring.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Prata / Análise Espectral Raman / Microcistinas / Toxinas Marinhas Idioma: En Revista: Food Chem Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Prata / Análise Espectral Raman / Microcistinas / Toxinas Marinhas Idioma: En Revista: Food Chem Ano de publicação: 2024 Tipo de documento: Article