Robot-assisted total knee arthroplasty system provides more precise control of the femoral rotation angle: A retrospective study.
Yan, Peng; Duan, Xudong; Lei, Yutian; Xing, Fangze; Cao, Ruomu; Luo, Sen; Chen, Yang; Liu, Zeyu; Wang, Kunzheng; Yang, Pei; Tian, Run.
Afiliação
  • Yan P; Department of Bone and Joint Surgery, The Second Affiliated Hospital of Xian Jiaotong University, Xi'an, China.
  • Duan X; Department of Bone and Joint Surgery, The Second Affiliated Hospital of Xian Jiaotong University, Xi'an, China.
  • Lei Y; Department of Bone and Joint Surgery, The Second Affiliated Hospital of Xian Jiaotong University, Xi'an, China.
  • Xing F; Department of Bone and Joint Surgery, The Second Affiliated Hospital of Xian Jiaotong University, Xi'an, China.
  • Cao R; Department of Bone and Joint Surgery, The Second Affiliated Hospital of Xian Jiaotong University, Xi'an, China.
  • Luo S; Department of Bone and Joint Surgery, The Second Affiliated Hospital of Xian Jiaotong University, Xi'an, China.
  • Chen Y; Department of Bone and Joint Surgery, The Second Affiliated Hospital of Xian Jiaotong University, Xi'an, China.
  • Liu Z; Department of Bone and Joint Surgery, The Second Affiliated Hospital of Xian Jiaotong University, Xi'an, China.
  • Wang K; Department of Bone and Joint Surgery, The Second Affiliated Hospital of Xian Jiaotong University, Xi'an, China.
  • Yang P; Department of Bone and Joint Surgery, The Second Affiliated Hospital of Xian Jiaotong University, Xi'an, China.
  • Tian R; Department of Bone and Joint Surgery, The Second Affiliated Hospital of Xian Jiaotong University, Xi'an, China.
Int J Med Robot ; 20(3): e2635, 2024 Jun.
Article em En | MEDLINE | ID: mdl-38733580
ABSTRACT

BACKGROUND:

Rotational alignment in total knee arthroplasty (TKA) is a crucial technical point that needs attention. We conducted a retrospective study to investigate whether a new robot-assisted TKA (RA-TKA) could improve the accuracy of rotational alignment and whether rotational alignment affects postoperative pain and functional evaluation of the knee.

METHODS:

A total of 136 consecutive patients who underwent TKA were included in this study. Half of the patients underwent RA-TKA and the other half underwent conventional TKA (CON-TKA) by the same group of surgeons. Collect the relevant parameters.

RESULTS:

The postoperative femoral rotation angle (FRA) was -0.72 ± 2.59° in the robot-assisted group and 1.13 ± 2.73° in the conventional group, and were statistically significantly different (p < 0.001).

CONCLUSION:

This study provides preliminary evidence that the RA-TKA provides more precise control of FRA than CON-TKA, and verifies that tibial rotation angle and combined rotation angle affect postoperative knee pain and functional evaluation.