Your browser doesn't support javascript.
loading
Equine laryngoplasty: Effects of three anchoring techniques in the muscular process and three positions for suture implantation in the cricoid cartilage.
Maire, Ulrika; Ducharme, Norm G; Rossignol, Anthony; Campos Schweitzer, Ariane; Rossignol, Fabrice.
Afiliação
  • Maire U; Grosbois Equine Clinic, Paris, France.
  • Ducharme NG; College of Veterinary Medicine, Cornell University, Ithaca, New York, USA.
  • Rossignol A; Grosbois Equine Clinic, Paris, France.
  • Campos Schweitzer A; Grosbois Equine Clinic, Paris, France.
  • Rossignol F; Grosbois Equine Clinic, Paris, France.
Vet Surg ; 2024 May 24.
Article em En | MEDLINE | ID: mdl-38787348
ABSTRACT

OBJECTIVE:

To compare the effects of three anchoring techniques in the muscular process and three positions of laryngoplasty suture implantation in the cricoid cartilage on abduction of the arytenoid cartilage and interaction with the cricoarytenoid dorsalis (CAD) muscle compartments. STUDY

DESIGN:

Experimental study. SAMPLE POPULATION Twenty-two cadaveric equine larynges.

METHODS:

Three implantation techniques were assessed in the left muscular process. They were the use of a titanium corkscrew (CS), a standard caudal passage using a Jamshidi needle (JCa), and a standard cranial passage using a Jamshidi needle (JCr). Each was assessed in combination with three caudal locations in the cricoid cartilage (right, left, and left lateral). Each suture combination was tightened to submaximal abduction (Dixon grade 2). Force on the suture, degree of larynx caudal rotation, and CAD muscle indentation were evaluated.

RESULTS:

The force required for optimal arytenoid cartilage abduction was lower (p < .01) for constructs involving a CS (7.45 ± 4 N). The CS also resulted in lower (p < .01) CAD muscle indentation (2.01 ± 1.25 mm) and less larynx rotation (9 ± 3.87°; adjusted p < .05).

CONCLUSION:

When inserted into the muscular process at the CAD tendon insertion point, the biomechanical properties of the CS reduced the force required for optimal arytenoid cartilage abduction. The CS also minimized interference with the CAD muscle compartments and reduced caudal displacement of the left arytenoid cartilage when it was under suture tension. CLINICAL

SIGNIFICANCE:

The CS implantation avoided larynx deformation and muscle interaction, offering the possibility to combine a nerve graft and laryngoplasty as a treatment for recurrent laryngeal neuropathy.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Vet Surg Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Vet Surg Ano de publicação: 2024 Tipo de documento: Article