Your browser doesn't support javascript.
loading
A LC-MS/MS method for the simultaneous determination of 6-cyanodopamine, 6-nitrodopamine, 6-nitrodopa, 6-nitroadrenaline and 6-bromodopamine in human plasma and its clinical application in patients with chronic kidney disease.
Ribeiro, Luiz Fernando; Babadopulos, Tainah; de Oliveira, Mariana G; Nishimaru, Flávio; Zatz, Roberto; Elias, Rosilene Motta; Moraes, Odorico; Moraes, Elisabete; Peterson, Larryn W; De Nucci, Gilberto.
Afiliação
  • Ribeiro LF; Department of Pharmacology, Faculty of Medical Sciences, State University of Campinas, Campinas, SP, Brazil.
  • Babadopulos T; Department of Pharmacology, Faculty of Medical Sciences, State University of Campinas, Campinas, SP, Brazil.
  • de Oliveira MG; Department of Pharmacology, Faculty of Medical Sciences, State University of Campinas, Campinas, SP, Brazil.
  • Nishimaru F; Division of Nephrology, Department of Internal Medicine, Faculty of Medicine, University of São Paulo, São Paulo, SP, Brazil.
  • Zatz R; Nephrology Center of Campinas, Campinas, SP, Brazil.
  • Elias RM; Division of Nephrology, Department of Internal Medicine, Faculty of Medicine, University of São Paulo, São Paulo, SP, Brazil.
  • Moraes O; Division of Nephrology, Department of Internal Medicine, Faculty of Medicine, University of São Paulo, São Paulo, SP, Brazil.
  • Moraes E; Clinical Pharmacology Unit, Drug Research and Development Center, Federal University of Ceará, Fortaleza, CE, Brazil.
  • Peterson LW; Clinical Pharmacology Unit, Drug Research and Development Center, Federal University of Ceará, Fortaleza, CE, Brazil.
  • De Nucci G; Department of Chemistry, Rhodes College, Memphis, Tennessee, USA.
Biomed Chromatogr ; 38(8): e5896, 2024 Aug.
Article em En | MEDLINE | ID: mdl-38797868
ABSTRACT
The aim of this study was to develop a high-performance liquid chromatography-tandem mass spectrometry method for the determination of 6-cyanodopamine, 6-nitrodopamine, 6-nitrodopa, 6-nitroadrenaline and 6-bromodopamine in human plasma samples. Strata-X 33 µm solid-phase extraction cartridges were used for the extraction of the catecholamines from human plasma samples. The catecholamines were separated in a 150 × 3 mm Shim-pack GIST C18-AQ column with 3 µm particle size, placed in an oven at 40°C and perfused with 82% mobile phase A (acetonitrile-H2O; 9010, v/v) + 0.4% acetic acid and 18% mobile phase B (deionized H2O) + 0.2% formic acid at a flow rate of 340 µl/min in isocratic mode. The injected volume was 4 µl and the run lasted 4 min. The method was linear from 0.1 to 20 ng/ml and the lower limit of quantification was 0.1 ng/ml for all analytes. The method was applied to evaluate the plasma levels of catecholamines in plasma of patients with chronic kidney disease and allowed the detection for the first time of circulating levels of the novel catecholamines 6-bromodopamine and 6-cyanodopamine.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Insuficiência Renal Crônica / Espectrometria de Massas em Tandem / Limite de Detecção Limite: Humans / Male / Middle aged Idioma: En Revista: Biomed Chromatogr Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Insuficiência Renal Crônica / Espectrometria de Massas em Tandem / Limite de Detecção Limite: Humans / Male / Middle aged Idioma: En Revista: Biomed Chromatogr Ano de publicação: 2024 Tipo de documento: Article