Utility of time in tight range (TITR) in evaluating metabolic control in pediatric and adult patients with type 1 diabetes in treatment with advanced hybrid closed-loop systems.
Endocrine
; 86(2): 539-545, 2024 Nov.
Article
em En
| MEDLINE
| ID: mdl-38814372
ABSTRACT
PURPOSE:
To analyze the time in tight range (TITR), and its relationship with other glucometric parameters in patients with type 1 diabetes (T1D) treated with advanced hybrid closed-loop (AHCL) systems.METHODS:
A prospective observational study was conducted on pediatric and adult patients with T1D undergoing treatment with AHCL systems for at least 3 months. Clinical variables and glucometric parameters before and after AHCL initiation were collected.RESULTS:
A total of 117 patients were evaluated. Comparison of metabolic control after AHCL initiation showed significant improvements in HbA1c (6.9 ± 0.9 vs. 6.6 ± 0.5%, p < 0.001), time in range (TIR) (68.2 ± 11.5 vs. 82.5 ± 6.9%, p < 0.001), TITR (43.7 ± 10.8 vs. 57.3 ± 9.7%, p < 0.001), glucose management indicator (GMI) (6.9 ± 0.4 vs. 6.6 ± 0.3%, p < 0.001), time below range (TBR) 70-54 mg/dl (4.3 ± 4.5 vs. 2.0 ± 1.4%, p < 0.001), and time above range (TAR) > 180 mg/dl (36.0 ± 7.6 vs. 15.1 ± 6.4%, p < 0.001). Coefficient of variation (CV) also improved (36.3 ± 5.7 vs. 30.6 ± 3.7, p < 0.001), while time between 140-180 mg/dl remained unchanged. In total, 76.3% achieved TITR > 50% (100% pediatric). Correlation analysis between TITR and TIR and GRI showed a strong positive correlation, modified by glycemic variability.CONCLUSIONS:
AHCL systems achieve significant improvements in metabolic control (TIR > 70% in 93.9% patients). The increase in TIR was not related to an increase in TIR 140-180 mg/dl. Despite being closely related to TIR, TITR allows for a more adequate discrimination of the achieved control level, especially in a population with good initial metabolic control. The correlation between TIR and TITR is directly influenced by the degree of glycemic variability.Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Glicemia
/
Sistemas de Infusão de Insulina
/
Diabetes Mellitus Tipo 1
/
Controle Glicêmico
/
Hipoglicemiantes
/
Insulina
Limite:
Adolescent
/
Adult
/
Child
/
Female
/
Humans
/
Male
/
Middle aged
Idioma:
En
Revista:
Endocrine
Ano de publicação:
2024
Tipo de documento:
Article