Your browser doesn't support javascript.
loading
Visible-light-driven photoelectrochemical sensor based on conjugated microporous polymer-grafted graphene for o-aminophenol detection.
Qin, Qiu Jing; Xiang, Gang; Xu, Jiangfen; Li, Wenzhuo; Huang, Qinying; Liu, Fengping; Zhang, Cuizhong; Zhang, Zhengfa; Huang, Wei; Peng, Jinyun.
Afiliação
  • Qin QJ; College of Chemical and Biological Engineering, Guangxi Minzu Normal University, Chongzuo 532200, China. xgshmily@163.com.
  • Xiang G; College of Chemical and Biological Engineering, Guangxi Minzu Normal University, Chongzuo 532200, China. xgshmily@163.com.
  • Xu J; Photochemical Sensing and Regional Environmental Analysis Laboratory, Guangxi Minzu Normal University, Chongzuo 532200, China.
  • Li W; Guangxi Institute for Drug Contyol, Nanning 530022, China.
  • Huang Q; Institute for Food and Drug Control of Chongzuo, Chongzuo 532200, China.
  • Liu F; College of Chemical and Biological Engineering, Guangxi Minzu Normal University, Chongzuo 532200, China. xgshmily@163.com.
  • Zhang C; College of Chemical and Biological Engineering, Guangxi Minzu Normal University, Chongzuo 532200, China. xgshmily@163.com.
  • Zhang Z; Photochemical Sensing and Regional Environmental Analysis Laboratory, Guangxi Minzu Normal University, Chongzuo 532200, China.
  • Huang W; College of Chemical and Biological Engineering, Guangxi Minzu Normal University, Chongzuo 532200, China. xgshmily@163.com.
  • Peng J; Photochemical Sensing and Regional Environmental Analysis Laboratory, Guangxi Minzu Normal University, Chongzuo 532200, China.
Anal Methods ; 16(24): 3895-3906, 2024 Jun 20.
Article em En | MEDLINE | ID: mdl-38828983
ABSTRACT
The pollutant o-aminophenol (o-AP) presents considerable risk to environmental safety, and its detection is therefore critical. Although various optical and electrochemical methods have been proposed for the detection of o-AP, there are a limited number of detection methods based on photoelectrochemical (PEC) sensors. In this study, a sensitive visible-light-driven PEC sensor was developed for o-AP detection in water. A conjugated microporous polymer (CMP)-coated graphene heterostructure (CMP-rGO) was synthesized and used to develop a PEC sensor. Under optimal conditions, the proposed sensor exhibited a high sensitivity of 0.03 µM with a wide linear range of 0.0034-37.6 µM. The PEC sensor also displayed acceptable repeatability and reproducibility, good long-term stability, and excellent recovery (98-102%). In addition, the binding patterns of CMP to o-AP and o-AP analog molecules were analyzed by molecular docking. Therefore, this study provides a new and feasible PEC sensor-based detection scheme for o-AP detection.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Anal Methods Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Anal Methods Ano de publicação: 2024 Tipo de documento: Article