ABSTRACT

Background:

Iatrogenic aortic valve injury during cardiovascular catheterization interventions is extremely rare. Severe aortic regurgitation that ensues can be catastrophic and the management is typically with surgical valve replacement or repair. Percutaneous management of native pure aortic regurgitation is difficult due to anatomical challenges and the limitations of current transcatheter heart valve technology to anchor in the absence of leaflet or annular calcification. Case

Summary:

An 82-year-old female underwent rotational atherectomy (RA) for a severely calcified stenosis of the left anterior descending artery. The patient was discharged well following placement of two drug eluting stents. She represented to hospital 7 days later with acute pulmonary oedema. Bedside transthoracic echocardiography demonstrated new, severe AR with preserved left ventricular size and function. Review of the prior percutaneous coronary intervention revealed significant trauma to the aortic valve during RA, with contrast seen refluxing into the LV during diastole, evolving throughout the procedure. Given the patient was not an operative candidate, an oversized transcatheter aortic valve was successfully implanted. In the post-operative setting, the patient suffered a stroke. Extensive hypoattenuated leaflet thickening (HALT) and thrombus was seen on dedicated 4D CT imaging. She made full neurological recovery and valve function returned to normal following a period of anticoagulation.

Conclusion:

Although iatrogenic aortic valve laceration is rare, this case highlights several important learning points including the importance of good guide catheter support during RA; the feasibility of Transcatheter Aortic Valve Replacement for pure native AR; and the detection and management of HALT.