Your browser doesn't support javascript.
loading
Preparation of amphiphilic poly(divinylbenzene-co-N-vinylpyrrolidone)-functionalized polydopamine magnetic nanoadsorbents for enrichment of synthetic cannabinoids in wastewater.
Li, Xiuchen; Jiang, Le; Di, Bin; Hu, Chi.
Afiliação
  • Li X; Department of Pharmacy, China Pharmaceutical University, No. 24 Tongjiaxiang Road, Nanjing 210009, PR China. dibin@cpu.edu.cn.
  • Jiang L; China National Narcotics Control Commission-China Pharmaceutical University Joint Laboratory on Key Technologies of Narcotics Control, No. 24 Tongjiaxiang Road, Nanjing 210009, PR China.
  • Di B; Department of Pharmacy, China Pharmaceutical University, No. 24 Tongjiaxiang Road, Nanjing 210009, PR China. dibin@cpu.edu.cn.
  • Hu C; China National Narcotics Control Commission-China Pharmaceutical University Joint Laboratory on Key Technologies of Narcotics Control, No. 24 Tongjiaxiang Road, Nanjing 210009, PR China.
Anal Methods ; 16(24): 3968-3982, 2024 Jun 20.
Article em En | MEDLINE | ID: mdl-38853581
ABSTRACT
Concerns have been raised about synthetic cannabinoids (SCs), which are among the most often trafficked and used illegal substances. An analytical method that holds promise for determining illicit drug use in the general population is wastewater-based epidemiology (WBE). Unfortunately, the concentration of SCs in wastewater is often extremely low on account of their hydrophobic nature, thus presenting a significant obstacle to the accurate detection and quantification of SCs using WBE. In this study, we present novel magnetic nanomaterials as amphiphilic adsorbents for pretreatment of wastewater using magnetic solid phase extraction (MSPE). Polydopamine-modified Fe3O4 nanoparticles were used as the magnetic core and further functionalized with poly(divinylbenzene-N-vinylpyrrolidone). Coupled with UHPLC-MS/MS analysis, an analytical method to simultaneously detect nine SCs at trace-levels in wastewater was developed and validated, enriching 50 mL wastewater to 100 µL with limits of detection (LOD) being 0.005-0.5 ng L-1, limits of quantification (LOQ) being 0.01-1.0 ng L-1, recoveries ranging from 73.99 to 110.72%, and the intra- and inter-day precision's relative standard deviations less than 15%. In comparison to the time-consuming conventional column-based solid phase extraction, the entire MSPE procedure from sample pre-treatment to data acquisition could be finished in one hour, thus largely facilitating the WBE method for drug surveillance and control.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Polímeros / Poluentes Químicos da Água / Canabinoides / Espectrometria de Massas em Tandem / Extração em Fase Sólida / Limite de Detecção / Águas Residuárias / Indóis Idioma: En Revista: Anal Methods Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Polímeros / Poluentes Químicos da Água / Canabinoides / Espectrometria de Massas em Tandem / Extração em Fase Sólida / Limite de Detecção / Águas Residuárias / Indóis Idioma: En Revista: Anal Methods Ano de publicação: 2024 Tipo de documento: Article