Your browser doesn't support javascript.
loading
Improving analytical performance for pesticides and mycotoxins determination in Brazilian table olives: one extraction and one analysis.
Reichert, Bárbara; Pizzutti, Ionara Regina; Jänisch, Bárbara Daiana; Zorzella Fontana, Marlos Eduardo.
Afiliação
  • Reichert B; HUSM - University Hospital of Santa Maria, Pharmacy Sector (SFH), 1000 Roraima Ave, Santa Maria, RS, 97105-900, Brazil.
  • Pizzutti IR; UFSM - Federal University of Santa Maria, Chemistry Department, Center of Research and Analysis of Residues and Contaminants (CEPARC), 1000 Roraima Ave, Santa Maria, RS, 97105-900, Brazil. ionara.pizzutti@ceparc.com.br.
  • Jänisch BD; UFSM - Federal University of Santa Maria, Chemistry Department, Center of Research and Analysis of Residues and Contaminants (CEPARC), 1000 Roraima Ave, Santa Maria, RS, 97105-900, Brazil. ionara.pizzutti@ceparc.com.br.
  • Zorzella Fontana ME; UFSM - Federal University of Santa Maria, Chemistry Department, Center of Research and Analysis of Residues and Contaminants (CEPARC), 1000 Roraima Ave, Santa Maria, RS, 97105-900, Brazil. ionara.pizzutti@ceparc.com.br.
Anal Methods ; 16(25): 4124-4135, 2024 Jun 27.
Article em En | MEDLINE | ID: mdl-38860427
ABSTRACT
This paper describes an extensive study in which a multiclass QuEChERS based approach was optimized for determination of 150 pesticides and 7 mycotoxins in table olives. Three versions of QuEChERS were evaluated and compared (unbuffered, citrate and acetate buffering). A combination of EMR-Lipid cartridges and liquid nitrogen or freezer freezing out were tested for clean-up of the oily olive extracts. Analysis of the extracts were performed by LC-MS/MS triple quadrupole. The best results were achieved using acetate QuEChERS with liquid nitrogen for clean-up. For validation, organic olives were ground and spiked at 4 concentrations with pesticides and mycotoxins (n = 5). The linearity of the calibration curves was assessed by analyzing calibration standards of 7 concentrations which were prepared separately in acetonitrile and in blank olive extract (n = 5). The validation study demonstrated that the calculated r2 was ≥0.99 for 144 pesticides and 6 mycotoxins, when the calibration curves were prepared in matrix extract, showing satisfactory linearity. Matrix effects were within the range of ±20% for only 46 pesticides and one mycotoxin. Then, to ensure reliable quantification, calibration standards had to be matrix-matched. In accuracy experiments 138 pesticides and 6 mycotoxins presented recoveries from 70 to 120% and RSD ≤ 20% for at least 2 of the 4 spike concentrations evaluated, being successfully validated. The integrated QuEChERS and LC-MS/MS method meet MRL for 11 of the 21 pesticides regulated for olives in Brazil and for 132 pesticides which are regulated in the EU law. Eleven commercial table olive samples were analyzed and 4 of them tested positive for pesticides. All the positive samples violate the Brazilian law and one sample violates also the European law.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Praguicidas / Olea / Espectrometria de Massas em Tandem / Micotoxinas País/Região como assunto: America do sul / Brasil Idioma: En Revista: Anal Methods Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Praguicidas / Olea / Espectrometria de Massas em Tandem / Micotoxinas País/Região como assunto: America do sul / Brasil Idioma: En Revista: Anal Methods Ano de publicação: 2024 Tipo de documento: Article