Your browser doesn't support javascript.
loading
Multivariate optimization and validation of 200 pesticide residues in the banana matrix by GC-MS/MS.
Ahire, Tushar Rajaram; Thasale, Rupal Rajesh; Das, Ankita; Kulkarni, Nikhil Pradip; Vyas, Dhyan Mineshkumar; Perumal, Sivaperumal.
Afiliação
  • Ahire TR; Chemical Sciences Division, ICMR - National Institute of Occupational Health, Meghani Nagar, Ahmedabad, India. sivaperumal.p@gov.in.
  • Thasale RR; Department of Biochemistry and Forensic Science, Gujarat University, Ahmedabad, India.
  • Das A; Chemical Sciences Division, ICMR - National Institute of Occupational Health, Meghani Nagar, Ahmedabad, India. sivaperumal.p@gov.in.
  • Kulkarni NP; Chemical Sciences Division, ICMR - National Institute of Occupational Health, Meghani Nagar, Ahmedabad, India. sivaperumal.p@gov.in.
  • Vyas DM; National Forensic Sciences University, Tripura Campus, India.
  • Perumal S; Chemical Sciences Division, ICMR - National Institute of Occupational Health, Meghani Nagar, Ahmedabad, India. sivaperumal.p@gov.in.
Anal Methods ; 16(26): 4268-4284, 2024 Jul 04.
Article em En | MEDLINE | ID: mdl-38884146
ABSTRACT
GC-MS/MS has been observed from past studies to be an appropriate choice for designing a simple, efficient and sensitive analytical technique. Accordingly, the linearity and working range, Method Limit of Detection (MLOD), Method Limit of Quantification (MLOQ), accuracy, precision (intra-day and inter-day), Matrix Effect (ME) and selectivity were analyzed for the assessment of 200 pesticide residues [organophosphorus pesticides (OPP), organochlorine pesticides (OCP), organonitrogen pesticides (ONP), synthetic pyrethroid pesticides (SPP), and herbicide methyl esters (HME)] in the banana matrix. The procedure involved QuEChERS (quick, easy, cheap, effective, rugged, and safe) extraction and clean-up with Multi-Walled Carbon Nanotubes (MWCNTs) and Primary Secondary Amine (PSA) wherein the factors were optimized using the Plackett-Burman and central composite designs. The performance of the method in order to quantitate 200 pesticides at trace levels was evaluated by matrix-matched calibration. The linearity was observed to range from 1 to 100 µg L-1 with determination coefficient (r2) > 0.99. Recovery studies were conducted at 2 levels, 10 µg kg-1 and 25 µg kg-1, and the values obtained were in the range of 71-116% and 72-119%, respectively. The Relative Standard Deviation (RSD) was observed to be less than 20% in line with the recommended guidelines (SANTE/11312/2021). The MLOD and MLOQ were found to be in the range of 0.45-6.33 µg kg-1 and 1.44-9.59 µg kg-1 respectively. The developed method was applied satisfactorily to analyse banana samples cultivated in different regions of Gujarat, India.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Resíduos de Praguicidas / Musa / Limite de Detecção / Cromatografia Gasosa-Espectrometria de Massas Idioma: En Revista: Anal Methods Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Resíduos de Praguicidas / Musa / Limite de Detecção / Cromatografia Gasosa-Espectrometria de Massas Idioma: En Revista: Anal Methods Ano de publicação: 2024 Tipo de documento: Article