Your browser doesn't support javascript.
loading
Performance Evaluation of a Novel Artificial Intelligence-Assisted Digital Microscopy System for the Routine Analysis of Bone Marrow Aspirates.
Bagg, Adam; Raess, Philipp W; Rund, Deborah; Bhattacharyya, Siddharth; Wiszniewska, Joanna; Horowitz, Alon; Jengehino, Darrin; Fan, Guang; Huynh, Michelle; Sanogo, Abdoulaye; Avivi, Irit; Katz, Ben-Zion.
Afiliação
  • Bagg A; Department of Pathology and Laboratory Medicine, University of Pennsylvania, Philadelphia, Pennsylvania.
  • Raess PW; Department of Pathology and Laboratory Medicine, Oregon Health & Science University, Portland, Oregon.
  • Rund D; Division of Hematology, Tel Aviv Sourasky Medical Center, Tel Aviv, Israel.
  • Bhattacharyya S; Department of Pathology and Laboratory Medicine, University of Pennsylvania, Philadelphia, Pennsylvania.
  • Wiszniewska J; Department of Pathology and Laboratory Medicine, Oregon Health & Science University, Portland, Oregon.
  • Horowitz A; Division of Hematology, Tel Aviv Sourasky Medical Center, Tel Aviv, Israel.
  • Jengehino D; Department of Pathology and Laboratory Medicine, University of Pennsylvania, Philadelphia, Pennsylvania.
  • Fan G; Department of Pathology and Laboratory Medicine, Oregon Health & Science University, Portland, Oregon.
  • Huynh M; Department of Pathology and Laboratory Medicine, University of Pennsylvania, Philadelphia, Pennsylvania.
  • Sanogo A; Department of Pathology and Laboratory Medicine, University of Pennsylvania, Philadelphia, Pennsylvania.
  • Avivi I; Division of Hematology, Tel Aviv Sourasky Medical Center, Tel Aviv, Israel; Faculty of Medical and Health Sciences, Tel Aviv University, Tel Aviv, Israel.
  • Katz BZ; Division of Hematology, Tel Aviv Sourasky Medical Center, Tel Aviv, Israel; Faculty of Medical and Health Sciences, Tel Aviv University, Tel Aviv, Israel; Division of Clinical Laboratories, Tel Aviv Sourasky Medical Center, Tel Aviv, Israel. Electronic address: benzik@tlvmc.gov.il.
Mod Pathol ; 37(9): 100542, 2024 Jun 17.
Article em En | MEDLINE | ID: mdl-38897451
ABSTRACT
Bone marrow aspiration (BMA) smear analysis is essential for diagnosis, treatment, and monitoring of a variety of benign and neoplastic hematological conditions. Currently, this analysis is performed by manual microscopy. We conducted a multicenter study to validate a computational microscopy approach with an artificial intelligence-driven decision support system. A total of 795 BMA specimens (615 Romanowsky-stained and 180 Prussian blue-stained) from patients with neoplastic and other clinical conditions were analyzed, comparing the performance of the Scopio Labs X100 Full Field BMA system (test method) with manual microscopy (reference method). The system provided an average of 1,385 ± 536 (range, 0-3,131) cells per specimen for analysis. An average of 39.98 ± 19.64 fields of view (range, 0-140) per specimen were selected by the system for analysis, of them 87% ± 21% (range, 0%-100%) were accepted by the qualified operators. These regions were included in an average of 17.62 ± 7.24 regions of interest (range, 1-50) per specimen. The efficiency, sensitivity, and specificity for primary and secondary marrow aspirate characteristics (maturation, morphology, and count assessment), as well as overall interuser agreement, were evaluated. The test method showed a high correlation with the reference method for comprehensive BMA evaluation, both on Romanowsky- (90.85% efficiency, 81.61% sensitivity, and 92.88% specificity) and Prussian blue-stained samples (90.0% efficiency, 81.94% sensitivity, and 93.38% specificity). The overall agreement between the test and reference methods for BMA assessment was 91.1%. For repeatability and reproducibility, all standard deviations and coefficients of variation values were below the predefined acceptance criteria both for discrete measurements (coefficient of variation below 20%) and differential measurements (SD below 5%). The high degree of correlation between the digital decision support system and manual microscopy demonstrates the potential of this system to provide a high-quality, accurate digital BMA analysis, expediting expert review and diagnosis of BMA specimens, with practical applications including remote BMA evaluation and possibly new opportunities for the research of normal and neoplastic hematopoiesis.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Mod Pathol Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Mod Pathol Ano de publicação: 2024 Tipo de documento: Article