Your browser doesn't support javascript.
loading
How Many Imaging Studies Do Patients With Neuromuscular Early Onset Scoliosis (EOS) Receive?
Lin, Adrian J; Chen, Vivian; Wong, Cynthis; Tamrazi, Benita; Skaggs, David L; Illingworth, Kenneth D; Heffernan, Michael J; Andras, Lindsay M.
Afiliação
  • Lin AJ; Jackie and Gene Autry Orthopedic Center.
  • Chen V; Jackie and Gene Autry Orthopedic Center.
  • Wong C; Department of Radiology, Children's Hospital Los Angeles.
  • Tamrazi B; Department of Orthopaedics, Cedars-Sina Medical Center, Los Angeles, CA.
  • Skaggs DL; Department of Orthopaedics, Baylor Scott and White Health, Dallas, TX.
  • Illingworth KD; Department of Orthopaedics, Baylor Scott and White Health, Dallas, TX.
  • Heffernan MJ; Jackie and Gene Autry Orthopedic Center.
  • Andras LM; Jackie and Gene Autry Orthopedic Center.
J Pediatr Orthop ; 44(8): e727-e731, 2024 Sep 01.
Article em En | MEDLINE | ID: mdl-38938111
ABSTRACT

BACKGROUND:

Children with neuromuscular early onset scoliosis (EOS) receive numerous radiographic studies both from orthopaedic and other specialties. Ionizing radiation doses delivered by computed tomography (CT) are reportedly 100 times higher than conventional radiography. The purpose of this study was to evaluate the number of radiographic studies ordered for neuromuscular EOS patients during their care.

METHODS:

Retrospective review at a tertiary children's hospital from January 2010 to June 2021 included all patients with neuromuscular EOS followed by an orthopaedic specialist for a minimum of 3 years. Patients were excluded if the majority of their nonorthopaedic care was provided by outside institutions.

RESULTS:

Eighteen patients met inclusion criteria with mean follow up of 6.4±2.3 years. A total of 1312 plain radiographs and 35 CT scans were performed. Of the plain radiographs, 34.7% were ordered by orthopaedic providers and 65.3% (857/1312) were ordered by other providers. Of the CT scans, 4 were ordered by orthopaedic providers, while 88.5% (21/35) were ordered by other providers. An average of 74.7 (range 29 to 124) radiographs and 1.9 (range 0 to 9) CT scans ordered over the course of each patient's treatment for an average of 13.0±6.0 radiographs and 0.3 CT scans per year.

CONCLUSIONS:

With an average of 75 radiographs and 1.9 CT scans performed per patient, consideration for steps to limit exposure to ionizing radiation should be made a particularly high priority in this unique subset of patients. This requires interdisciplinary coordination as 65% of the radiographs and over 80% of the CT scans were ordered by nonorthopaedic providers. LEVEL OF EVIDENCE Level III.