Your browser doesn't support javascript.
loading
Comparative analysis of a bulk optode based on a valinomycin ionophore and a nano-optode in micelles with pluronic F-127 for the quantification of potassium in aqueous solutions.
Villanueva, Miguel; Vega-Chacón, Jaime; Picasso, Gino.
Afiliação
  • Villanueva M; Technology of Materials for Environmental Remediation (TecMARA) Research Group, Faculty of Sciences, National University of Engineering, Av. Tupac Amaru 210, Lima 15333, Peru. gpicasso@uni.edu.pe.
  • Vega-Chacón J; Technology of Materials for Environmental Remediation (TecMARA) Research Group, Faculty of Sciences, National University of Engineering, Av. Tupac Amaru 210, Lima 15333, Peru. gpicasso@uni.edu.pe.
  • Picasso G; Technology of Materials for Environmental Remediation (TecMARA) Research Group, Faculty of Sciences, National University of Engineering, Av. Tupac Amaru 210, Lima 15333, Peru. gpicasso@uni.edu.pe.
Anal Methods ; 16(28): 4710-4723, 2024 Jul 18.
Article em En | MEDLINE | ID: mdl-38948955
ABSTRACT
In this work, two types of optical sensors were prepared for the quantification of potassium the bulk optode (BO) and nano-optode (NO). The BO was prepared using three main components the ionophore valinomycin, the ion exchanger tetrakis(4-chlorophenyl) potassium borate (K-TCPB), and the chromoionophore ETH 5294 (CHI). The optimal composition was found to be in a ratio of [1 1 1]. The NO was prepared by miniaturizing the BO through sonication in surfactant Pluronic F-127. The working range for the linear calibration model of BO was from 10-6 to 1.0 M K+ with a LODBO = 0.31 µM, meanwhile for NO was from 10-4 to 1.0 M K+ with a LODNO = 30.3 µM. Both optodes were tested for selectivity towards K+ in the presence of alkaline and alkaline earth ions, with a selectivity coefficient > 1.0. Furthermore, precision and stability studies of BO and NO were performed for three levels of K+ concentrations, 10-6, 10-3, 1.0 M for BO and 10-4, 10-2, 1.0 M for NO, showing a good homogeneity of the NO in the whole concentration range. However, an excessive variability was obtained for BO at 1.0 M K+. Therefore, the NO represents a potential tool for quantification of K+.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Anal Methods Ano de publicação: 2024 Tipo de documento: Article