Your browser doesn't support javascript.
loading
Biportal Endoscopic Spinal Cord Stimulation Paddle Lead Implantation: Technical Note and Preliminary Clinical Results.
Miao, Xi-Zi; Gao, Ding-Zhi; Yang, Shao-Mei; Guo, Xiao-Li; Wen, Ya-Feng; Shi, Lei; Chu, Lei.
Afiliação
  • Miao XZ; Department of Pain Medicine, the Second Affiliated Hospital of Chongqing Medical University, Chongqing, China; Department of Spine Surgery, the Second Affiliated Hospital of Chongqing Medical University, Chongqing, China.
  • Gao DZ; Department of Spine Surgery, the Second Affiliated Hospital of Chongqing Medical University, Chongqing, China.
  • Yang SM; Department of Spine Surgery, the Second Affiliated Hospital of Chongqing Medical University, Chongqing, China.
  • Guo XL; Department of Pain Medicine, the Second Affiliated Hospital of Chongqing Medical University, Chongqing, China.
  • Wen YF; Department of Spine Surgery, the Second Affiliated Hospital of Chongqing Medical University, Chongqing, China.
  • Shi L; Department of Pain Medicine, the Second Affiliated Hospital of Chongqing Medical University, Chongqing, China; Department of Spine Surgery, the Second Affiliated Hospital of Chongqing Medical University, Chongqing, China.
  • Chu L; Department of Pain Medicine, the Second Affiliated Hospital of Chongqing Medical University, Chongqing, China; Department of Spine Surgery, the Second Affiliated Hospital of Chongqing Medical University, Chongqing, China. Electronic address: 302939@hospital.cqmu.edu.cn.
Neuromodulation ; 27(6): 1062-1067, 2024 Aug.
Article em En | MEDLINE | ID: mdl-38958631
ABSTRACT

OBJECTIVE:

This study aims to elucidate a novel, minimally invasive surgical technique using a biportal endoscope for the implantation of spinal cord stimulation (SCS) paddle leads and to report the preliminary results of its clinical application. MATERIALS AND

METHODS:

The perioperative data of patients who underwent the biportal endoscopic SCS paddle lead implantation in our department were collected; the surgical procedure was delineated, and the clinical outcomes were assessed.

RESULTS:

From February 2022 to December 2023, six patients underwent biportal endoscopic SCS paddle lead implantation. The median follow-up time was nine months (range one to three months). The median intraoperative blood loss was 30 mL (range 25-50 mL), and the median operative time was 87.5 minutes (range 75-110 minutes). One patient experienced severe neck pain during the operation, whereas the other five patients experienced no surgical complications. One patient was found to have a slight lead migration three months after surgery, which did not affect the therapeutic effect. The median visual analogue scale (VAS) of the surgical area was 0.5 (range 0-2), 2.5 (range 1-4), and 0.5 (range 0-1) during the operation and one day and one week after the operation, respectively. The median VAS of the six patients' primary disease was 8 (range 7-9) before surgery and 2.5 (range 1-4) at the last postoperative follow-up (pain reduction ≥50%).

CONCLUSION:

Paddle lead systems for SCS can be implanted successfully using a biportal endoscopic technique.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Eletrodos Implantados / Estimulação da Medula Espinal Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Neuromodulation Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Eletrodos Implantados / Estimulação da Medula Espinal Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Neuromodulation Ano de publicação: 2024 Tipo de documento: Article