Your browser doesn't support javascript.
loading
Preparation and study of a capillary electrochromatographic column prepared by conjugating ß-CD COFs and gold-poly glycidyl methacrylate nanoparticles.
Long, Ke; Guan, Jin; Yu, Jiatong; Zhang, Dongxiang; Shi, Shuang.
Afiliação
  • Long K; School of Chemical Technology, Liaoning & Shenyang Key Laboratory of Functional Dye and Pigment, Shenyang University of Chemical Technology, Shenyang, P. R. China.
  • Guan J; School of Chemical Technology, Liaoning & Shenyang Key Laboratory of Functional Dye and Pigment, Shenyang University of Chemical Technology, Shenyang, P. R. China. Guanj0418@163.com.
  • Yu J; School of Chemical Technology, Liaoning & Shenyang Key Laboratory of Functional Dye and Pigment, Shenyang University of Chemical Technology, Shenyang, P. R. China.
  • Zhang D; School of Chemical Technology, Liaoning & Shenyang Key Laboratory of Functional Dye and Pigment, Shenyang University of Chemical Technology, Shenyang, P. R. China.
  • Shi S; School of Chemical Technology, Liaoning & Shenyang Key Laboratory of Functional Dye and Pigment, Shenyang University of Chemical Technology, Shenyang, P. R. China.
Mikrochim Acta ; 191(8): 457, 2024 07 09.
Article em En | MEDLINE | ID: mdl-38980449
ABSTRACT
A new enantioselective open-tubular capillary electrochromatography (OT-CEC) was developed employing ß-cyclodextrin covalent organic frameworks (ß-CD COFs) conjugated gold-poly glycidyl methacrylate nanoparticles (Au-PGMA NPs) as a stationary phase. The resulting coating layer on the inner wall of the fabricated capillary column was characterized by scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FT-IR), energy dispersive spectroscopy (EDS), and electroosmotic flow (EOF) experiments. The performance of the fabricated capillary column was evaluated by CEC using enantiomers of seven model analytes, including two proton pump inhibitors (PPIs, omeprazole and tenatoprazole), three amino acids (AAs, tyrosine, phenylalanine, and tryptophan), and two fluoroquinolones (FQs, gatifloxacin and sparfloxacin). The influences of coating time, buffer concentration, buffer pH, and applied voltage on enantioseparation were investigated to obtain satisfactory enantioselectivity. In the optimum conditions, the enantiomers of seven analytes were fully resolved within 10 min with high resolutions of 3.03 to 5.25. The inter- to intra-day and column-to-column repeatabilities of the fabricated capillary column were lower than 4.26% RSD. Furthermore, molecular docking studies were performed based on the chiral fabricated column and as ligand isomers of analytes using Auto Dock Tools. The binding energies and interactions acquired from docking results of analytes supported the experimental data.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Beta-Ciclodextrinas / Eletrocromatografia Capilar / Ouro Idioma: En Revista: Mikrochim Acta Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Beta-Ciclodextrinas / Eletrocromatografia Capilar / Ouro Idioma: En Revista: Mikrochim Acta Ano de publicação: 2024 Tipo de documento: Article