Your browser doesn't support javascript.
loading
Evaluation and comparison of one-step real-time PCR and one-step RT-LAMP methods for detection of SARS-CoV-2.
Hanifehpour, Hooman; Ashrafi, Fatemeh; Siasi, Elham; Fallahi, Shirzad.
Afiliação
  • Hanifehpour H; Department of Microbiology, Faculty of Biological Sciences, North Tehran Branch, Islamic Azad University, Tehran, Iran.
  • Ashrafi F; Department of Microbiology, Faculty of Biological Sciences, North Tehran Branch, Islamic Azad University, Tehran, Iran.
  • Siasi E; Department of Microbiology, Faculty of Biological Sciences, North Tehran Branch, Islamic Azad University, Tehran, Iran.
  • Fallahi S; Hepatitis Research Center, Lorestan University of Medical Sciences, Khorramabad, Iran. Falahi.sh@lums.ac.ir.
BMC Infect Dis ; 24(1): 679, 2024 Jul 09.
Article em En | MEDLINE | ID: mdl-38982392
ABSTRACT

BACKGROUND:

There is an increasing disease trend for SARS-COV-2, so need a quick and affordable diagnostic method. It should be highly accurate and save costs compared to other methods. The purpose of this research is to achieve these goals.

METHODS:

This study analyzed 342 samples using TaqMan One-Step RT-qPCR and fast One-Step RT-LAMP (Reverse Transcriptase Loop-Mediated Isothermal Amplification). The One-Step LAMP assay was conducted to assess the sensitivity and specificity.

RESULTS:

The research reported positive samples using two different methods. In the RT-LAMP method, saliva had 92 positive samples (26.9%) and 250 negative samples (73.09%) and nasopharynx had 94 positive samples (27.4%) and 248 negative samples (72.51%). In the RT-qPCR method, saliva had 86 positive samples (25.1%) and 256 negative samples (74.8%) and nasopharynx had 93 positive samples (27.1%) and 249 negative samples (72.8%). The agreement between the two tests in saliva and nasopharynx samples was 93% and 94% respectively, based on Cohen's kappa coefficient (κ) (P < 0.001). The rate of sensitivity in this technique was reported at a dilution of 1 × 101 and 100% specificity.

CONCLUSIONS:

Based on the results of the study the One-Step LAMP assay has multiple advantages. These include simplicity, cost-effectiveness, high sensitivity, and specificity. The One-Step LAMP assay shows promise as a diagnostic tool. It can help manage disease outbreaks, ensure prompt treatment, and safeguard public health by providing rapid, easy-to-use testing.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Saliva / Nasofaringe / Sensibilidade e Especificidade / Técnicas de Amplificação de Ácido Nucleico / Técnicas de Diagnóstico Molecular / Reação em Cadeia da Polimerase em Tempo Real / SARS-CoV-2 / COVID-19 Limite: Humans Idioma: En Revista: BMC Infect Dis Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Saliva / Nasofaringe / Sensibilidade e Especificidade / Técnicas de Amplificação de Ácido Nucleico / Técnicas de Diagnóstico Molecular / Reação em Cadeia da Polimerase em Tempo Real / SARS-CoV-2 / COVID-19 Limite: Humans Idioma: En Revista: BMC Infect Dis Ano de publicação: 2024 Tipo de documento: Article