Your browser doesn't support javascript.
loading
Measurement of human peritoneal surface area using artificial intelligence software in abdominal computed tomography.
Choi, Seung Joon; Park, Ji-Hyeon; Jeon, Youngbae; Lee, Donghyuk; Baek, Jeong-Heum.
Afiliação
  • Choi SJ; Department of Radiology, Gachon University Gil Medical Center, Gachon University College of Medicine, Incheon, Korea.
  • Park JH; Department of Surgery, Gachon University Gil Medical Center, Gachon University College of Medicine, Incheon, Korea.
  • Jeon Y; Department of Surgery, Gachon University Gil Medical Center, Gachon University College of Medicine, Incheon, Korea.
  • Lee D; Department of Biomedical Engineering, Gachon University College of Medicine, Incheon, Korea.
  • Baek JH; Department of Surgery, Gachon University Gil Medical Center, Gachon University College of Medicine, Incheon, Korea.
Korean J Clin Oncol ; 20(1): 6-12, 2024 May.
Article em En | MEDLINE | ID: mdl-38988013
ABSTRACT

PURPOSE:

The calculation of the intraperitoneal organ surface area is important for understanding their anatomical structure and for conducting basic and clinical studies on diseases related to the peritoneum. To measure the intraperitoneal surface area in a living body by applying artificial intelligence (AI) techniques to the abdominal cavity using computed tomography and to prepare clinical indicators for application to the abdominal cavity.

METHODS:

Computed tomography images of ten adult males and females with a healthy body mass index and ten adults diagnosed with colon cancer were analyzed to determine the peritoneal and intraperitoneal surface areas of the organs. The peritoneal surface was segmented and three-dimensionally modeled using AI medical imaging software. In addition to manual work, three-dimensional editing, filtering, and connectivity checks were performed to improve work efficiency and accuracy. The colon and small intestine surface areas were calculated using the mean length and diameter. The abdominal cavity surface area was defined as the sum of the intraperitoneal area and the surface areas of each organ.

RESULTS:

The mean peritoneal surface area of all participants was measured as 10,039 ± 241 cm2 (males 10,224 ± 171 cm2 and females 9,854 ± 134 cm2). Males had a 3.7% larger peritoneal surface area than females, with a statistically significant difference (P < 0.001).

CONCLUSION:

The abdominal cavity surface area can be measured using AI techniques and is expected to be used as basic data for clinical applications.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Korean J Clin Oncol Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Korean J Clin Oncol Ano de publicação: 2024 Tipo de documento: Article