Your browser doesn't support javascript.
loading
Cell-Electrode Models for Impedance Analysis of Epithelial and Endothelial Monolayers Cultured on Microelectrodes.
Chiu, Wei-Chih; Chen, Wei-Ling; Lai, Yi-Ting; Hung, Yu-Han; Lo, Chun-Min.
Afiliação
  • Chiu WC; Department of Biomedical Engineering, National Yang Ming Chiao Tung University, Taipei 11221, Taiwan.
  • Chen WL; Department of Biomedical Engineering, National Yang Ming Chiao Tung University, Taipei 11221, Taiwan.
  • Lai YT; Research Center for Applied Sciences, Academia Sinica, Taipei 11529, Taiwan.
  • Hung YH; Department of Neurology, University of California, Irvine, CA 92697, USA.
  • Lo CM; Department of Biomedical Engineering, National Yang Ming Chiao Tung University, Taipei 11221, Taiwan.
Sensors (Basel) ; 24(13)2024 Jun 28.
Article em En | MEDLINE | ID: mdl-39000992
ABSTRACT
Electric cell-substrate impedance sensing has been used to measure transepithelial and transendothelial impedances of cultured cell layers and extract cell parameters such as junctional resistance, cell-substrate separation, and membrane capacitance. Previously, a three-path cell-electrode model comprising two transcellular pathways and one paracellular pathway was developed for the impedance analysis of MDCK cells. By ignoring the resistances of the lateral intercellular spaces, we develop a simplified three-path model for the impedance analysis of epithelial cells and solve the model equations in a closed form. The calculated impedance values obtained from this simplified cell-electrode model at frequencies ranging from 31.25 Hz to 100 kHz agree well with the experimental data obtained from MDCK and OVCA429 cells. We also describe how the change in each model-fitting parameter influences the electrical impedance spectra of MDCK cell layers. By assuming that the junctional resistance is much smaller than the specific impedance through the lateral cell membrane, the simplified three-path model reduces to a two-path model, which can be used for the impedance analysis of endothelial cells and other disk-shaped cells with low junctional resistances. The measured impedance spectra of HUVEC and HaCaT cell monolayers nearly coincide with the impedance data calculated from the two-path model.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Impedância Elétrica / Células Endoteliais / Células Epiteliais / Microeletrodos Limite: Animals / Humans Idioma: En Revista: Sensors (Basel) Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Impedância Elétrica / Células Endoteliais / Células Epiteliais / Microeletrodos Limite: Animals / Humans Idioma: En Revista: Sensors (Basel) Ano de publicação: 2024 Tipo de documento: Article