Your browser doesn't support javascript.
loading
A simulation-guided approach to the selection of RPLC columns for platform small molecule separations.
Liu, Zhiyang; Foley, Joe P; Shackman, Jonathan G; Wang, Qinggang; Zhou, Yiyang.
Afiliação
  • Liu Z; Department of Chemistry, Drexel University, 32 South 32nd St., Philadelphia, PA 19104, USA.
  • Foley JP; Bristol Myers Squibb, 1 Squibb Dr, New Brunswick, NJ 08901, USA. Electronic address: jfoley@drexel.edu.
  • Shackman JG; Bristol Myers Squibb, 1 Squibb Dr, New Brunswick, NJ 08901, USA. Electronic address: jonathan.shackman@bms.com.
  • Wang Q; Department of Chemistry, Drexel University, 32 South 32nd St., Philadelphia, PA 19104, USA.
  • Zhou Y; Department of Chemistry, Drexel University, 32 South 32nd St., Philadelphia, PA 19104, USA.
J Chromatogr A ; 1730: 465131, 2024 Aug 16.
Article em En | MEDLINE | ID: mdl-39002508
ABSTRACT
Simulations were conducted to evaluate the potential of several hundred reversed-phase columns to separate small molecules. By calculating the retention factor of compounds in randomly generated virtual mixtures via the HSM (hydrophobic subtraction model) and applying basic chromatography theory, the simulation can estimate the retention time and peak width of every virtual compound and calculate the resolution between every adjacent pair of compounds. A preferred column set based on the number of successful separations of randomly generated virtual mixtures was developed. The tandem-column liquid chromatography (TC-LC) approach can separate 53.2 % of the 16-compound samples using 20 tandem-column pairs, while a single-column approach can only separate 42.6 % of the 16-compound samples with 20 single columns. The preferred set of columns obtained from the simulation was almost the same as the empirical set of columns previously obtained. In screening applications, TC-LC can achieve a comparably successful separation factor (selectivity) with a smaller column inventory (nine 50-mm columns) compared to the larger inventory needed by single-column LC (twenty-one 100-mm columns).
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cromatografia de Fase Reversa Idioma: En Revista: J Chromatogr A Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cromatografia de Fase Reversa Idioma: En Revista: J Chromatogr A Ano de publicação: 2024 Tipo de documento: Article