Electrocochleography in Cochlear Implant Recipients: Correlating Maximum Response With Residual Hearing.
Andonie, Raphael R; Wimmer, Wilhelm; Schraivogel, Stephan; Mantokoudis, Georgios; Caversaccio, Marco; Weder, Stefan.
Afiliação
  • Andonie RR; Hearing Research Laboratory, ARTORG Center for Biomedical Engineering Research, Bern University Hospital, University of Bern, Bern, Switzerland.
  • Wimmer W; Department of Otorhinolaryngology, Head & Neck Surgery, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
  • Schraivogel S; Department of Otorhinolaryngology, Head & Neck Surgery, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
  • Mantokoudis G; Department of Otorhinolaryngology, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany.
  • Caversaccio M; Hearing Research Laboratory, ARTORG Center for Biomedical Engineering Research, Bern University Hospital, University of Bern, Bern, Switzerland.
  • Weder S; Department of Otorhinolaryngology, Head & Neck Surgery, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
Ear Hear ; 2024 Jul 16.
Article em En | MEDLINE | ID: mdl-39010266
ABSTRACT

OBJECTIVES:

Electrocochleography (ECochG) is increasingly recognized as a biomarker for assessing inner ear function in cochlear implant patients. This study aimed to objectively determine intraoperative cochlear microphonic (CM) amplitude patterns and correlate them with residual hearing in cochlear implant recipients, addressing the limitations in current ECochG analysis that often depends on subjective visual assessment and overlook the intracochlear measurement location.

DESIGN:

In this prospective study, we investigated intraoperative pure-tone ECochG following complete electrode insertion in 31 patients. We used our previously published objective analysis method to determine the maximum CM amplitude and the associated electrode position for each electrode array. Using computed tomography, we identified electrode placement and determined the corresponding tonotopic frequency using Greenwood's function. Based on this, we calculated the tonotopic shift, that is, the difference between the stimulation frequency and the estimated frequency of the electrode with the maximum CM amplitude. We evaluated the association between CM amplitude, tonotopic shift, and preoperative hearing thresholds using linear regression analysis.

RESULTS:

CM amplitudes showed high variance, with values ranging from -1.479 to 4.495 dBµV. We found a statistically significant negative correlation ( ) between maximum CM amplitudes and preoperative hearing thresholds. In addition, a significant association ( ) between the tonotopic shift and preoperative hearing thresholds was observed. Tonotopic shifts of the maximum CM amplitudes occurred predominantly toward the basal direction.

CONCLUSIONS:

The combination of objective signal analysis and the consideration of intracochlear measurement locations enhances the understanding of cochlear health and overcomes the obstacles of current ECochG analysis. We could show the link between intraoperative CM amplitudes, their spatial distributions, and preoperative hearing thresholds. Consequently, our findings enable automated analysis and bear the potential to enhance specificity of ECochG, reinforcing its role as an objective biomarker for cochlear health.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Ear Hear Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Ear Hear Ano de publicação: 2024 Tipo de documento: Article