Your browser doesn't support javascript.
loading
Mechanical effect of different patterns for preparation of orthodontic appliances: An experimental study.
Tian, Shiyu; Dai, Juan; Ahmad, Waheed; Liang, Kanhui; Tan, Qiyun; Deng, Hao; Jiang, Feifei; Xiong, Jing; Cao, Jun; Xia, Zeyang.
Afiliação
  • Tian S; Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences.
  • Dai J; Department of Stomatology, Shenzhen University General Hospital, Shenzhen University.
  • Ahmad W; Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences.
  • Liang K; University of Chinese Academy of Sciences.
  • Tan Q; Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences.
  • Deng H; Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences.
  • Jiang F; Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences.
  • Xiong J; Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences.
  • Cao J; Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences.
  • Xia Z; Department of Stomatology, Shenzhen University General Hospital, Shenzhen University.
Dent Mater J ; 2024 Jul 20.
Article em En | MEDLINE | ID: mdl-39034130
ABSTRACT
Archwire bending is the key to orthodontic treatment, and multi-time bendings are inevitable during manual and robotic automated bending. The purpose of this paper is to quantitatively evaluate the mechanical effects of the different preparation modes and to compare the mechanical properties of the orthodontic loops in one and multiple bends. Three types of typical stainless steel orthodontic loops (vertical loop, T-loop, and L-loop) were used to quantify the mechanical effect of patterns for preparation by experimental comparison between loops with different bending times by using an orthodontic force tester (OFT). The results were statistically analyzed by t-test. The fracture test of the stainless steel archwire was also carried out, and the bending times at fracture were recorded. Results of the tests indicate that one-time and multi-time bending have a significant mechanical effect on orthodontic appliances. Multi-time bending causes significant mechanical decreases and can damage the appliances.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Dent Mater J Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Dent Mater J Ano de publicação: 2024 Tipo de documento: Article