Your browser doesn't support javascript.
loading
Needle size for thyroid fine needle aspiration cytology. A single institution experience.
Cianci, Pasquale; Tumolo, Rocco; Conversano, Ivana; Travaglia, Damiano; Trigiante, Giuseppe; Lantone, Giuliano; Lizzi, Vincenzo; Cappiello, Miriam; Montagna, Marco; Curci, Fabio Pio; Restini, Enrico.
Afiliação
  • Cianci P; Department of Surgery and Traumatology, ASL BAT, Lorenzo Bonomo Hospital, Andria, Italy.
  • Tumolo R; Department of Surgery and Traumatology, ASL BAT, Lorenzo Bonomo Hospital, Andria, Italy.
  • Conversano I; Department of Surgery and Traumatology, ASL BAT, Lorenzo Bonomo Hospital, Andria, Italy.
  • Travaglia D; Department of Surgery and Traumatology, ASL BAT, Lorenzo Bonomo Hospital, Andria, Italy.
  • Trigiante G; Department of Surgery and Traumatology, ASL BAT, Lorenzo Bonomo Hospital, Andria, Italy.
  • Lantone G; Department of Surgery and Traumatology, ASL BAT, Lorenzo Bonomo Hospital, Andria, Italy.
  • Lizzi V; Department of Medical and Surgical Sciences, Azienda Ospedaliero-Universitaria Policlinico Riuniti, Foggia, Italy.
  • Cappiello M; Department of Surgery and Traumatology, ASL BAT, Lorenzo Bonomo Hospital, Andria, Italy.
  • Montagna M; Department of Surgery and Traumatology, ASL BAT, Lorenzo Bonomo Hospital, Andria, Italy.
  • Curci FP; Department of Surgery and Traumatology, ASL BAT, Lorenzo Bonomo Hospital, Andria, Italy.
  • Restini E; Department of Surgery and Traumatology, ASL BAT, Lorenzo Bonomo Hospital, Andria, Italy.
Front Surg ; 11: 1368614, 2024.
Article em En | MEDLINE | ID: mdl-39035112
ABSTRACT

Background:

Fine needle aspiration cytology (FNAC) is an invasive diagnostic technique which is widely used for the cytological diagnosis of thyroid nodules. This procedure is generally widely tolerated by patients, albeit often accompanied by local pain and discomfort. Despite various proposals of execution methods, no approach is universally accepted,especially regarding the size of the needle to be used for sampling. Needle gauge preferences vary across regions, with 25-gauge needles more common in Western countries and 22-gauge needles favored in Asian countries. Complications associated with larger needles have been studied but remain inconclusive. Materials and

methods:

Over one year, we conducted 300 FNAC procedures under ultrasound guidance, employing both 22-gauge and 25-gauge needles. In no patient was local anesthesia performed before starting the procedure, which in all was performed by the same operator. Similarly the cytological examination of the material taken was performed by a single operator. Patients, 105 males and 195 females, were divided into two groups of 150 each based on the needle size used.

Results:

Patients treated with 22-gauge needles reported higher levels of pain during the procedure and increased discomfort afterward. Similarly, a greater incidence of hematomas and vasovagal reactions was noted in this group. However, the cell sample obtained and diagnostic response rates were consistent across both groups.

Conclusion:

On the basis of our observations we concluded that the size of the needle used is irrelevant for the purposes of the diagnostic result, as long as the procedure is performed by expert personnel. However, the 25-gauge needle is preferable because it's more tolerated and accepted by patients. Our results do not represent a single and conclusive verdict, but they could represent the starting point for further research.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Front Surg Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Front Surg Ano de publicação: 2024 Tipo de documento: Article