The application of B1 inhomogeneity-corrected variable flip angle T1 mapping for assessing liver fibrosis.
Zou, Jie; Jiang, Yanli; Fan, Fengxian; Yang, Pin; Gan, Tiejun; Yang, Tingli; Li, Min; Ding, Yuan; Wang, Shaoyu; Zhang, Jing.
Afiliação
  • Zou J; Department of Magnetic Resonance, The Second Hospital & Clinical Medical School, Lanzhou University, PR China; Gansu Province Clinical Research Center for Functional and Molecular Imaging, Lanzhou 730030, China.
  • Jiang Y; Department of Magnetic Resonance, The Second Hospital & Clinical Medical School, Lanzhou University, PR China; Gansu Province Clinical Research Center for Functional and Molecular Imaging, Lanzhou 730030, China.
  • Fan F; Department of Magnetic Resonance, The Second Hospital & Clinical Medical School, Lanzhou University, PR China; Gansu Province Clinical Research Center for Functional and Molecular Imaging, Lanzhou 730030, China.
  • Yang P; Department of Magnetic Resonance, The Second Hospital & Clinical Medical School, Lanzhou University, PR China; Gansu Province Clinical Research Center for Functional and Molecular Imaging, Lanzhou 730030, China.
  • Gan T; Department of Magnetic Resonance, The Second Hospital & Clinical Medical School, Lanzhou University, PR China; Gansu Province Clinical Research Center for Functional and Molecular Imaging, Lanzhou 730030, China.
  • Yang T; Department of Magnetic Resonance, The Second Hospital & Clinical Medical School, Lanzhou University, PR China; Gansu Province Clinical Research Center for Functional and Molecular Imaging, Lanzhou 730030, China.
  • Li M; Department of Magnetic Resonance, The Second Hospital & Clinical Medical School, Lanzhou University, PR China; Gansu Province Clinical Research Center for Functional and Molecular Imaging, Lanzhou 730030, China.
  • Ding Y; Department of Magnetic Resonance, The Second Hospital & Clinical Medical School, Lanzhou University, PR China; Gansu Province Clinical Research Center for Functional and Molecular Imaging, Lanzhou 730030, China.
  • Wang S; MR Scientific Marketing, Siemens Healthineers, Xi'an 710065, PR China.
  • Zhang J; Department of Magnetic Resonance, The Second Hospital & Clinical Medical School, Lanzhou University, PR China; Gansu Province Clinical Research Center for Functional and Molecular Imaging, Lanzhou 730030, China. Electronic address: lztong2001@163.com.
Magn Reson Imaging ; 113: 110215, 2024 Nov.
Article em En | MEDLINE | ID: mdl-39047851
ABSTRACT

PURPOSE:

The aim of this study was to evaluate the diagnostic accuracy of the B1 inhomogeneity-corrected variable flip angle (VFA) method using native T1 values in the staging of liver fibrosis.

METHODS:

Eighty-three patients who presented for liver biopsy due to varying degrees of liver damage, underwent MR examinations and had T1-mapping images of the liver acquired using the B1 inhomogeneity-corrected VFA VIBE method. Among them, 65 patients underwent Fibroscan, and their results were used to evaluate the elasticity of liver tissue. Additionally, T1-mapping images were collected from 19 normal control patients. Independent sample t-tests were used to analyze the correlation between T1 mapping and Fibroscan. The diagnostic efficacy of T1 mapping in patients with different stages of liver fibrosis was evaluated using receiver operating characteristic (ROC) curves.

RESULTS:

The consistency between different observer groups was intraclass correlation coefficient (ICC) =0.802. T1 mapping demonstrated significant differences between mid-stage liver fibrosis (S = 2) and late-stage liver fibrosis (S = 3), as well as moderate inflammation (G = 2) and severe inflammation (G = 3), P < 0.05. The Area Under Curve(AUC) values of T1 mapping for early liver fibrosis (S ≥ 1), significant liver fibrosis (S ≥ 2), advanced liver fibrosis (S ≥ 3), and end-stage liver fibrosis (S = 4) were 0.760, 0.709, 0.790, and 0.768, respectively. T1 mapping combined with Fibroscan had an AUC value of 0.860.

CONCLUSIONS:

The B1 inhomogeneity-corrected VFA T1 mapping may be useful for the staging of liver fibrosis. It has a superior diagnostic efficiency for diagnosing advanced fibrosis (≥S3), while native T1 values combined with Fibroscan have potential value for the staging of liver fibrosis.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Fígado / Cirrose Hepática Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Magn Reson Imaging Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Fígado / Cirrose Hepática Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Magn Reson Imaging Ano de publicação: 2024 Tipo de documento: Article