Your browser doesn't support javascript.
loading
Freestanding Films of Reduced Graphene Oxide Fully Decorated with Prussian Blue Nanoparticles for Hydrogen Peroxide Sensing.
Martins, Vitor H N; da Silva, Monize M; Gonçalves, Daniel A; Presser, Volker; Husmann, Samantha; Souza, Victor H R.
Afiliação
  • Martins VHN; Faculty of Exact Science and Technology, Universidade Federal da Grande Dourados, Dourados, Mato Grosso do Sul 79804-970, Brazil.
  • da Silva MM; Faculty of Exact Science and Technology, Universidade Federal da Grande Dourados, Dourados, Mato Grosso do Sul 79804-970, Brazil.
  • Gonçalves DA; Faculty of Exact Science and Technology, Universidade Federal da Grande Dourados, Dourados, Mato Grosso do Sul 79804-970, Brazil.
  • Presser V; INM-Leibniz Institute for New Materials, Campus D2-2, 66123 Saarbrücken, Germany.
  • Husmann S; Department of Materials Science & Engineering, Saarland University, Campus D2 2, 66123 Saarbrücken, Germany.
  • Souza VHR; Saarene-Saarland Center for Energy Materials and Sustainability, Campus C4 2, 66123 Saarbrücken, Germany.
ACS Omega ; 9(29): 31569-31577, 2024 Jul 23.
Article em En | MEDLINE | ID: mdl-39072102
ABSTRACT
Developing thin, freestanding electrodes that work simultaneously as a current collector and electroactive material is pivotal to integrating portable and wearable chemical sensors. Herein, we have synthesized graphene/Prussian blue (PB) electrodes for hydrogen peroxide detection (H2O2) using a two-step method. First, an reduced graphene oxide/PAni/Fe2O3 freestanding film is prepared using a doctor blade technique, followed by the electrochemical deposition of PB nanoparticles over the films. The iron oxide nanoparticles work as the iron source for the heterogeneous electrochemical deposition of the nanoparticles in a ferricyanide solution. The size of the PB cubes electrodeposited over the graphene-based electrodes was controlled by the number of voltammetric cycles. For H2O2 sensing, the PB10 electrode achieved the lowest detection and quantification limits, 2.00 and 7.00 µM, respectively. The findings herein evidence the balance between the structure of the graphene/PB-based electrodes with the electrochemical performance for H2O2 detection and pave the path for developing new freestanding electrodes for chemical sensors.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: ACS Omega Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: ACS Omega Ano de publicação: 2024 Tipo de documento: Article