Your browser doesn't support javascript.
loading
Generating luminescent Graphene quantum Dots from Tryptophan: Fluorosensors for hydrogen peroxide in cancer cells.
Asif, Seikh; Das, Debashree; Basu, Shalmali; Morgan, David; Datta, Aparna; Sen, Kamalika.
Afiliação
  • Asif S; Department of Chemistry, University of Calcutta, 92 APC Road, Kolkata 700009, India.
  • Das D; Department of Chemistry, University of Calcutta, 92 APC Road, Kolkata 700009, India.
  • Basu S; Department of Chemistry, University of Calcutta, 92 APC Road, Kolkata 700009, India.
  • Morgan D; Cardiff Catalysis Institute, School of Chemistry, Cardiff University, Park Place, Cardiff, CF10 3AT, United Kingdom.
  • Datta A; UGC-DAE Consortium for Scientific Research, Kolkata Centre, III/LB-8, Bidhannagar, Kolkata 700098, India.
  • Sen K; Department of Chemistry, University of Calcutta, 92 APC Road, Kolkata 700009, India. Electronic address: kschem@caluniv.ac.in.
Spectrochim Acta A Mol Biomol Spectrosc ; 323: 124887, 2024 Dec 15.
Article em En | MEDLINE | ID: mdl-39096676
ABSTRACT
Herein, we report a single step synthesis of highly fluorescent Graphene Quantum Dots (GQDs) using tryptophan and glycerol as precursors via pyrolysis. The morphological and functional characterization of the prepared GQDs was performed using PXRD, FTIR, TEM, XPS and zeta potential measurements. The prepared GQDs found their practical application in ultrasensitive detection of an emerging potential cancer biomarker, H2O2, by exploiting the fluorescence quenching behaviour of H2O2. To evaluate the detection sensitivity, a series of various concentrations of H2O2 was spiked to biomatrices like, serum and MCF-7 (human breast cancer cell line) cell lysate medium. A remarkably low limit of detection (LOD) was found in serum medium (139.5 pM) which further improved in MCF-7 cell lysate medium (LOD 61.43 pM). Moreover, the sensing capacity of the GQDs was further validated in presence of various physiological variables such as glucose, cholesterol, insulin and nitrite. Sensing assay was also carried out in HaCaT (human keratinocyte cell line) cell lysate medium to compare the performance of our prepared sensor but the non-linearity of the F0/F versus H2O2 concentration plot pointed towards the conduciveness of the MCF-7 cell lysate medium for sensitive detection of H2O2.The mechanism behind the sensing was also explored using spectroscopic methods.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrometria de Fluorescência / Triptofano / Pontos Quânticos / Limite de Detecção / Grafite / Peróxido de Hidrogênio Limite: Humans Idioma: En Revista: Spectrochim Acta A Mol Biomol Spectrosc Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrometria de Fluorescência / Triptofano / Pontos Quânticos / Limite de Detecção / Grafite / Peróxido de Hidrogênio Limite: Humans Idioma: En Revista: Spectrochim Acta A Mol Biomol Spectrosc Ano de publicação: 2024 Tipo de documento: Article