Your browser doesn't support javascript.
loading
Improvement of Functional Mobility Using a Hip-Wearable Exoskeleton Robot in Guillain-Barré Syndrome With Residual Gait Disturbance: A Case Report.
Yabuki, Jun; Yoshikawa, Kenichi; Koseki, Kazunori; Ishibashi, Kiyoshige; Matsushita, Akira; Kohno, Yutaka.
Afiliação
  • Yabuki J; Department of Physical Therapy, Mejiro University, Saitama, JPN.
  • Yoshikawa K; Department of Physical Therapy, Ibaraki Prefectural University of Health Sciences Hospital, Ami, JPN.
  • Koseki K; Department of Physical Therapy, Ibaraki Prefectural University of Health Sciences Hospital, Ami, JPN.
  • Ishibashi K; Department of Physical Therapy, Ibaraki Prefectural University of Health Sciences Hospital, Ami, JPN.
  • Matsushita A; Department of Neurosurgery, Ibaraki Prefectural University of Health Sciences Hospital, Ami, JPN.
  • Kohno Y; Department of Neurology, Ibaraki Prefectural University of Health Sciences Hospital, Ami, JPN.
Cureus ; 16(7): e63882, 2024 Jul.
Article em En | MEDLINE | ID: mdl-39100052
ABSTRACT
Patients with Guillain-Barré syndrome (GBS) occasionally have residual gait disturbance one year after disease onset. We hypothesized that providing hip joint movement assistance can improve gait in patients with GBS and residual gait disturbance. A 78-year-old man with GBS showed improvement in gait following conventional rehabilitation and gait training using GAIT TRAINER HWA-01 (HWA-01; Honda Motor Co., Ltd., Tokyo, Japan), which is a hip-wearable exoskeleton robot. Initially, he presented with gastrointestinal symptoms, subsequently flaccid quadriplegia, and respiratory muscle paralysis. He was diagnosed with acute motor axonal neuropathy and was transferred to our hospital on day 185 after the disease onset. Seven months after rehabilitation, his walking ability plateaued. On day 382, a single-case study with ABABA design intervention, with conventional gait training in phase A and gait training using HWA-01 in phase B, was conducted. The primary outcomes included a comfortable walking speed, stride length, and cadence. Comfortable walking speed, stride length, and cadence statistically improved after gait training using HWA-01. Furthermore, improvement in exercise capacity and activities of daily living exceeded the minimal clinically important difference for the intervention. The use of the HWA-01 gait trainer potentially improves gait in patients with GBS who have residual gait disturbance.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Cureus Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Cureus Ano de publicação: 2024 Tipo de documento: Article