Transformer-Based Deep Learning Prediction of 10-Degree Humphrey Visual Field Tests From 24-Degree Data.
Shi, Min; Lokhande, Anagha; Tian, Yu; Luo, Yan; Eslami, Mohammad; Kazeminasab, Saber; Elze, Tobias; Shen, Lucy Q; Pasquale, Louis R; Wellik, Sarah R; De Moraes, Carlos Gustavo; Myers, Jonathan S; Zebardast, Nazlee; Friedman, David S; Boland, Michael V; Wang, Mengyu.
Afiliação
  • Shi M; Harvard Ophthalmology AI Lab, Schepens Eye Research Institute of Massachusetts Eye and Ear, Harvard Medical School, Boston, MA, USA.
  • Lokhande A; Harvard Ophthalmology AI Lab, Schepens Eye Research Institute of Massachusetts Eye and Ear, Harvard Medical School, Boston, MA, USA.
  • Tian Y; Harvard Ophthalmology AI Lab, Schepens Eye Research Institute of Massachusetts Eye and Ear, Harvard Medical School, Boston, MA, USA.
  • Luo Y; Harvard Ophthalmology AI Lab, Schepens Eye Research Institute of Massachusetts Eye and Ear, Harvard Medical School, Boston, MA, USA.
  • Eslami M; Harvard Ophthalmology AI Lab, Schepens Eye Research Institute of Massachusetts Eye and Ear, Harvard Medical School, Boston, MA, USA.
  • Kazeminasab S; Harvard Ophthalmology AI Lab, Schepens Eye Research Institute of Massachusetts Eye and Ear, Harvard Medical School, Boston, MA, USA.
  • Elze T; Harvard Ophthalmology AI Lab, Schepens Eye Research Institute of Massachusetts Eye and Ear, Harvard Medical School, Boston, MA, USA.
  • Shen LQ; Massachusetts Eye and Ear, Harvard Medical School, Boston, MA, USA.
  • Pasquale LR; Eye and Vision Research Institute, Icahn School of Medicine at Mount Sinai, New York, NY, USA.
  • Wellik SR; Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, FL, USA.
  • De Moraes CG; Edward S. Harkness Eye Institute, Columbia University Medical Center, New York, NY, USA.
  • Myers JS; Wills Eye Hospital, Thomas Jefferson University, Philadelphia, PA, USA.
  • Zebardast N; Massachusetts Eye and Ear, Harvard Medical School, Boston, MA, USA.
  • Friedman DS; Massachusetts Eye and Ear, Harvard Medical School, Boston, MA, USA.
  • Boland MV; Massachusetts Eye and Ear, Harvard Medical School, Boston, MA, USA.
  • Wang M; Harvard Ophthalmology AI Lab, Schepens Eye Research Institute of Massachusetts Eye and Ear, Harvard Medical School, Boston, MA, USA.
Transl Vis Sci Technol ; 13(8): 11, 2024 Aug 01.
Article em En | MEDLINE | ID: mdl-39110574
ABSTRACT

Purpose:

To predict 10-2 Humphrey visual fields (VFs) from 24-2 VFs and associated non-total deviation features using deep learning.

Methods:

We included 5189 reliable 24-2 and 10-2 VF pairs from 2236 patients, and 28,409 reliable pairs of macular OCT scans and 24-2 VF from 19,527 eyes of 11,560 patients. We developed a transformer-based deep learning model using 52 total deviation values and nine VF test features to predict 68 10-2 total deviation values. The mean absolute error, root mean square error, and the R2 were evaluation metrics. We further evaluated whether the predicted 10-2 VFs can improve the structure-function relationship between macular thinning and paracentral VF loss in glaucoma.

Results:

The average mean absolute error and R2 for 68 10-2 VF test points were 3.30 ± 0.52 dB and 0.70 ± 0.11, respectively. The accuracy was lower in the inferior temporal region. The model placed greater emphasis on 24-2 VF points near the central fixation point when predicting the 10-2 VFs. The inclusion of nine VF test features improved the mean absolute error and R2 up to 0.17 ± 0.06 dB and 0.01 ± 0.01, respectively. Age was the most important 24-2 VF test parameter for 10-2 VF prediction. The predicted 10-2 VFs achieved an improved structure-function relationship between macular thinning and paracentral VF loss, with the R2 at the central 4, 12, and 16 locations of 24-2 VFs increased by 0.04, 0.05 and 0.05, respectively (P < 0.001).

Conclusions:

The 10-2 VFs may be predicted from 24-2 data. Translational Relevance The predicted 10-2 VF has the potential to improve glaucoma diagnosis.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Campos Visuais / Glaucoma / Tomografia de Coerência Óptica / Testes de Campo Visual / Aprendizado Profundo Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Transl Vis Sci Technol Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Campos Visuais / Glaucoma / Tomografia de Coerência Óptica / Testes de Campo Visual / Aprendizado Profundo Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Transl Vis Sci Technol Ano de publicação: 2024 Tipo de documento: Article