Colonoscopy Quality Measures and Adherence to Follow-up Guidelines Among Endoscopists Participating in a United States Endoscopy Registry.
Shapiro, Jean A; Holub, Jennifer L; Dominitz, Jason A; Sabatino, Susan A; Nadel, Marion R.
Afiliação
  • Shapiro JA; Division of Cancer Prevention and Control, National Center for Chronic Disease Prevention and Health Promotion, Centers for Disease Control and Prevention, Atlanta, GA, USA. Electronic address: zga9@cdc.gov.
  • Holub JL; GI Quality Improvement Consortium, Ltd, Bethesda, MD, USA.
  • Dominitz JA; Division of Gastroenterology, Department of Medicine, Veterans Affairs Puget Sound Health Care System and University of Washington, Seattle, WA, USA.
  • Sabatino SA; Division of Cancer Prevention and Control, National Center for Chronic Disease Prevention and Health Promotion, Centers for Disease Control and Prevention, Atlanta, GA, USA.
  • Nadel MR; Division of Cancer Prevention and Control, National Center for Chronic Disease Prevention and Health Promotion, Centers for Disease Control and Prevention, Atlanta, GA, USA.
Gastrointest Endosc ; 2024 Aug 05.
Article em En | MEDLINE | ID: mdl-39111394
ABSTRACT
BACKGROUND AND

AIMS:

Colonoscopy screening can substantially reduce colorectal cancer incidence and mortality. Colonoscopies may achieve maximum benefit when they are performed with high quality and accompanied by follow-up recommendations that adhere to clinical guidelines. This study aimed to determine to what extent endoscopists met targets for colonoscopy quality from 2016 through 2019 (the most recent years prior to the COVID-19 pandemic).

METHODS:

We examined measures of colonoscopy quality and recommended follow-up intervals in the GI Quality Improvement Consortium, a large nationwide endoscopy registry. The analysis included over 2.5 million outpatient screening colonoscopies in average risk adults aged 50-75 years.

RESULTS:

At least 90% of endoscopists met performance targets for adequate bowel preparation, cecal intubation rate, and adenoma detection rate. However, nonadherence to guidelines for follow-up intervals was common. For patients with no colonoscopy findings, 12.0% received a follow-up interval recommendation of ≤5 years instead of the guideline-recommended 10 years. For patients with 1-2 small tubular adenomas, 13.5% received a follow-up interval recommendation of ≤3 years instead of the guideline-recommended 5-10 years. For patients with small sessile serrated polyps, 30.7% received a follow-up interval recommendation of ≤3 years instead of the guideline-recommended 5 years. Some patients with higher risk findings received a follow-up interval recommendation of ≥5 years instead of the guideline-recommended 3 years, including 18.2% of patients with advanced serrated lesions.

CONCLUSIONS:

Additional attention may be needed to achieve more consistent adherence to guidelines for colonoscopy follow-up recommendations.