New spin coated multilayer lactate biosensor for acidosis monitoring in continuous flow assisted with an electrochemical pH probe.
García-Guzmán, Juan José; Jiménez Heras, José Manuel; López-Iglesias, David; González-Álvarez, Rafael Jesús; Cubillana-Aguilera, Laura; González Macías, Carmen; Fernández Alba, Juan Jesús; Palacios-Santander, José María.
Afiliação
  • García-Guzmán JJ; Instituto de Investigación e Innovación Biomédica de Cádiz (INiBICA), Hospital Universitario 'Puerta del Mar', Universidad de Cádiz, 11009, Cádiz, Spain.
  • Jiménez Heras JM; Instituto de Investigación e Innovación Biomédica de Cádiz (INiBICA), Hospital Universitario 'Puerta del Mar', Universidad de Cádiz, 11009, Cádiz, Spain.
  • López-Iglesias D; Instituto de Investigación e Innovación Biomédica de Cádiz (INiBICA), Hospital Universitario 'Puerta del Mar', Universidad de Cádiz, 11009, Cádiz, Spain.
  • González-Álvarez RJ; Instituto de Investigación e Innovación Biomédica de Cádiz (INiBICA), Hospital Universitario 'Puerta del Mar', Universidad de Cádiz, 11009, Cádiz, Spain.
  • Cubillana-Aguilera L; Institute of Research on Electron Microscopy and Materials (IMEYMAT), Department of Analytical Chemistry, Faculty of Sciences, Campus de Excelencia Internacional del Mar (CEIMAR), Universidad de Cádiz, República Saharaui, S/N. 11510, Puerto Real, Cádiz, Spain. laura.cubillana@uca.es.
  • González Macías C; Departamento de Obstetricia y Ginecología, Hospital Universitario de Puerto Real, 11510, Puerto Real, Cádiz, Spain.
  • Fernández Alba JJ; Departamento de Obstetricia y Ginecología, Hospital Universitario de Puerto Real, 11510, Puerto Real, Cádiz, Spain. jjesus.fernandez@uca.es.
  • Palacios-Santander JM; Institute of Research on Electron Microscopy and Materials (IMEYMAT), Department of Analytical Chemistry, Faculty of Sciences, Campus de Excelencia Internacional del Mar (CEIMAR), Universidad de Cádiz, República Saharaui, S/N. 11510, Puerto Real, Cádiz, Spain.
Mikrochim Acta ; 191(9): 526, 2024 08 09.
Article em En | MEDLINE | ID: mdl-39120744
ABSTRACT
A LOx-based electrochemical biosensor for high-level lactate determination was developed. For the construction of the biosensor, chitosan and Nafion layers were integrated by using a spin coating procedure, leading to less porous surfaces in comparison with those recorded after a drop casting procedure. The analytical performance of the resulting biosensor for lactate determination was evaluated in batch and flow regime, displaying satisfactory results in both modes ranging from 0.5 to 20 mM concentration range for assessing the lactic acidosis. Finally, the lactate levels in raw serum samples were estimated using the biosensor developed and verified with a blood gas analyzer. Based on these results, the biosensor developed is promising for its use in healthcare environment, after its proper miniaturization. A pH probe based on common polyaniline-based electrochemical sensor was also developed to assist the biosensor for the lactic acidosis monitoring, leading to excellent results in stock solutions ranging from 6.0 to 8.0 mM and raw plasma samples. The results were confirmed by using two different approaches, blood gas analyzer and pH-meter. Consequently, the lactic acidosis monitoring could be achieved in continuous flow regime using both (bio)sensors.