Intraoperative zero-heat-flux thermometry overestimates nasopharyngeal temperature by 0.39 °C: an observational study in patients undergoing congenital heart surgery.
Brandes, Ivo F; Tirilomis, Theodor; Nemeth, Marcus; Wieditz, Johannes; Bräuer, Anselm.
Afiliação
  • Brandes IF; Department of Anesthesiology, Emergency and Intensive Care Medicine, University Medical Center Göttingen, Robert-Koch-Str. 40, 37075, Göttingen, Germany. ivo.brandes@med.uni-goettingen.de.
  • Tirilomis T; Department of Cardiac, Thoracic and Vascular Surgery, University Medical Center Göttingen, Göttingen, Germany.
  • Nemeth M; Department of Anesthesiology, Emergency and Intensive Care Medicine, University Medical Center Göttingen, Robert-Koch-Str. 40, 37075, Göttingen, Germany.
  • Wieditz J; Department of Anesthesiology, Emergency and Intensive Care Medicine, University Medical Center Göttingen, Robert-Koch-Str. 40, 37075, Göttingen, Germany.
  • Bräuer A; Department of Medical Statistics, University Medical Center Göttingen, Göttingen, Germany.
J Clin Monit Comput ; 2024 Aug 10.
Article em En | MEDLINE | ID: mdl-39127818
ABSTRACT
During surgery for congenital heart disease (CHD) temperature management is crucial. Vesical (Tves) and nasopharyngeal (TNPH) temperature are usually measured. Whereas Tves slowly responds to temperature changes, TNPH carries the risk of bleeding. The zero-heat-flux (ZHF) temperature monitoring systems SpotOn™ (TSpotOn), and Tcore™ (Tcore) measure temperature non-invasively. We evaluated accuracy and precision of the non-invasive devices, and of Tves compared to TNPH for estimating temperature. In this prospective observational study in pediatric and adult patients accuracy and precision of TSpotOn, Tcore, and Tves were analyzed using the Bland-Altman method. Proportion of differences (PoD) and Lin´s concordance correlation coefficient (LCC) were calculated. Data of 47 patients resulted in sets of matched measurements 1073 for TSpotOn vs. TNPH, 874 for Tcore vs. TNPH, and 1102 for Tves vs. TNPH. Accuracy was - 0.39 °C for TSpotOn, -0.09 °C for Tcore, and 0.07 °C for Tves. Precisison was between - 1.12 and 0.35 °C for TSpotOn, -0.88 to 0.71 °C for Tcore, and - 1.90 to 2.05 °C for Tves. PoD ≤ 0.5 °C were 71% for TSpotOn, 71% for Tcore, and 60% for Tves. LCC was 0.9455 for TSpotOn, 0.9510 for Tcore, and 0.9322 for Tves. Temperatures below 25.2 °C (TSpotOn) or 27.1 (Tcore) could not be recorded non-invasively, but only with Tves. Trial registration German Clinical Trials Register, DRKS00010720.