Your browser doesn't support javascript.
loading
Decoding Radiology Reports: Artificial Intelligence-Large Language Models Can Improve the Readability of Hand and Wrist Orthopedic Radiology Reports.
Butler, James J; Acosta, Ernesto; Kuna, Michael C; Harrington, Michael C; Rosenbaum, Andrew J; Mulligan, Michael T; Kennedy, John G.
Afiliação
  • Butler JJ; NYU Langone Health, New York, USA.
  • Acosta E; Albany Medical Center, NY, USA.
  • Kuna MC; Albany Medical Center, NY, USA.
  • Harrington MC; Albany Medical Center, NY, USA.
  • Rosenbaum AJ; Albany Medical Center, NY, USA.
  • Mulligan MT; Albany Medical Center, NY, USA.
  • Kennedy JG; NYU Langone Health, New York, USA.
Hand (N Y) ; : 15589447241267766, 2024 Aug 13.
Article em En | MEDLINE | ID: mdl-39138809
ABSTRACT

BACKGROUND:

The purpose of this study was to assess the effectiveness of an Artificial Intelligence-Large Language Model (AI-LLM) at improving the readability of hand and wrist radiology reports.

METHODS:

The radiology reports of 100 hand and/or wrist radiographs, 100 hand and/or wrist computed tomography (CT) scans, and 100 hand and/or wrist magnetic resonance imaging (MRI) scans were extracted. The following prompt command was inserted into the AI-LLM "Explain this radiology report to a patient in layman's terms in the second person [Report Text]." The report length, Flesch reading ease score (FRES), and Flesch-Kincaid reading level (FKRL) were calculated for the original radiology report and the AI-LLM-generated report. The accuracy of the AI-LLM report was assessed via a 5-point Likert scale. Any "hallucination" produced by the AI-LLM-generated report was recorded.

RESULTS:

There was a statistically significant improvement in mean FRES scores and FKRL scores in the AI-LLM-generated radiograph report, CT report, and MRI report. For all AI-LLM-generated reports, the mean reading level improved to below an eighth-grade reading level. The mean Likert score for the AI-LLM-generated radiograph report, CT report, and MRI report was 4.1 ± 0.6, 3.9 ± 0.6, and 3.9 ± 0.7, respectively. The hallucination rate in the AI-LLM-generated radiograph report, CT report, and MRI report was 3%, 6%, and 6%, respectively.

CONCLUSIONS:

This study demonstrates that AI-LLM effectively improves the readability of hand and wrist radiology reports, underscoring the potential application of AI-LLM as a promising and innovative patient-centric strategy to improve patient comprehension of their imaging reports.Level of Evidence IV.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Hand (N Y) Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Hand (N Y) Ano de publicação: 2024 Tipo de documento: Article