Your browser doesn't support javascript.
loading
Presoaking hamstring autograft with vancomycin does not jeopardize its biomechanical properties, including graft elongation, after cyclic loading.
Park, Hyung Jun; Yoon, Chan; Kang, Seung-Baik; Kim, Tae Woo; Chang, Chong Bum; Bae, Tae Soo; Chang, Moon Jong; Kwak, Dai-Soon.
Afiliação
  • Park HJ; Department of Orthopedic Surgery, Korea University College of Medicine, Ansan Hospital, Ansan, Republic of Korea.
  • Yoon C; Department of Orthopedic Surgery, Seoul Bumin Hospital, Seoul, Republic of Korea.
  • Kang SB; Department of Orthopedic Surgery, SMG-SNU Boramae Medical Center, Seoul National University College of Medicine, Seoul, Republic of Korea.
  • Kim TW; Department of Orthopedic Surgery, SMG-SNU Boramae Medical Center, Seoul National University College of Medicine, Seoul, Republic of Korea.
  • Chang CB; Department of Orthopedic Surgery, Seoul National University College of Medicine, Seoul National University Bundang Hospital, Seongnam, Republic of Korea.
  • Bae TS; Department of Biomedical Engineering (BME), Jungwon University, Goesan-gun, Republic of Korea.
  • Chang MJ; Department of Orthopedic Surgery, SMG-SNU Boramae Medical Center, Seoul National University College of Medicine, Seoul, Republic of Korea.
  • Kwak DS; Department of Anatomy, Catholic Institute for Applied Anatomy, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.
Article em En | MEDLINE | ID: mdl-39138856
ABSTRACT

PURPOSE:

Presoaking the graft with vancomycin before implantation has been shown to reduce the risk of postoperative infection after anterior cruciate ligament reconstruction (ACLR). However, the effects of presoaking on the graft biomechanical properties remain unclear. This study aimed to determine whether presoaking the graft with vancomycin affects the graft biomechanical properties and length after cyclic loading.

METHODS:

Ten paired (20 specimens) gracilis and semitendinous tendons were harvested from fresh-frozen human cadaveric specimens. Two tendons were folded in half to make four strands, and the grafts were randomized into the vancomycin and control groups. The graft was exposed to the antibiotic solution for 15 min (5 mg/mL) and prepared by mixing 1 g of vancomycin with 200 mL of normal saline (NaCl 0.9%). The control group was soaked in normal saline for 15 min. The prepared grafts were attached to the actuator of a dynamic tensile-testing machine. All grafts were tested with 3000 cycles of cyclic loading followed by a pull-to-failure. The cyclic loading protocol consisted of position and load control blocks to simulate the graft in vivo in the postoperative phase after ACLR.

RESULTS:

Presoaking in vancomycin did not jeopardize the biomechanical properties of the graft. In addition, presoaking with vancomycin did not elongate the grafts. No significant differences were found in the mean Young's modulus and the mean total elongation of the graft of the specimen between the vancomycin group and the control group.

CONCLUSION:

Presoaking the graft with vancomycin jeopardized neither its biomechanical properties nor elongation even after cyclic loading in this in vitro study. It is suggested that vancomycin presoaking could be considered a safe and effective preventive measure for postoperative infections after ACLR. LEVEL OF EVIDENCE Not applicable.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Knee Surg Sports Traumatol Arthrosc Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Knee Surg Sports Traumatol Arthrosc Ano de publicação: 2024 Tipo de documento: Article