Your browser doesn't support javascript.
loading
Nucleic acid-functionalized nanoscale porous carbon-based electrochemical genosensor for detection of Nocardia spp. in real samples.
Asaadi, Hanieh; Vojdani, Arastoo; Meshkat, Zahra; Sankian, Mojtaba; Farsiani, Hadi; Tavakoly Sany, Seyedeh Belin; Aryan, Ehsan; Hatamluyi, Behnaz.
Afiliação
  • Asaadi H; Antimicrobial Resistance Research Center, Mashhad University of Medical Sciences, Mashhad, Iran.
  • Vojdani A; Antimicrobial Resistance Research Center, Mashhad University of Medical Sciences, Mashhad, Iran.
  • Meshkat Z; Antimicrobial Resistance Research Center, Mashhad University of Medical Sciences, Mashhad, Iran.
  • Sankian M; Immunology Research Center, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran.
  • Farsiani H; Antimicrobial Resistance Research Center, Mashhad University of Medical Sciences, Mashhad, Iran.
  • Tavakoly Sany SB; Department of Health, Safety, and Environment Management, School of Health, Mashhad University of Medical Sciences, Mashhad, Iran; Social Determinants of Health Research Center, Mashhad University of Medical Sciences, Mashhad, Iran.
  • Aryan E; Antimicrobial Resistance Research Center, Mashhad University of Medical Sciences, Mashhad, Iran. Electronic address: AryanE@mums.ac.ir.
  • Hatamluyi B; Antimicrobial Resistance Research Center, Mashhad University of Medical Sciences, Mashhad, Iran; Student Research Committee, Mashhad University of Medical Sciences, Mashhad, Iran. Electronic address: Behnazhatamluyi@gmail.com.
Talanta ; 280: 126706, 2024 Dec 01.
Article em En | MEDLINE | ID: mdl-39153257
ABSTRACT
In this study, a porous carbon derived from a metal-organic framework (PCMOF) as a target-responsive material functionalized with Nocardia particular antisense ssDNA oligonucleotide (ssDNA capture probe) was developed to construct a simple genosensor based on biogatekeeper strategy for sensitive detection of Nocardia in complex biological samples. The PCMOF with suitable pores volume was used to encapsulate electroactive dye methylene blue (MB), and the ssDNA capture probe was used as a gatekeeper to cap PCMOF. Without the presence of Nocardia target, the electrochemical signal of trapped MB was high. Upon adding the target, the hybridization of ssDNA capture probe and target led to the formation of a probe-target double-stranded (dsDNA) structure which dissociated from PCMOF and allowed MB molecules to be released. Therefore, the electrochemical signal of the genosensor decreased. The detection of Nocardia was accomplished by observing variations in the MB peak current intensity in a dose-dependent manner. For this genosensor, a linearity range from 10-18 to 10-7 M for synthetic ssDNA target and 10 to 108 copies/mL for two standard isolates, Nocardia farcinica PTCC 1309 and Nocardia brasiliensis ATCC 19296 as well as for clinical isolates (identified as Nocardia otitidiscaviarum) was observed, respectively. The detection limit (DL) values were 0.54 aM for synthetic ssDNA target and 5, 7, and 4 copies/mL for N. farcinica, N. brasiliensis, and N. otitidiscaviarum, respectively. This genosensor was also characterized by good specificity, reproducibility, and stability.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: DNA de Cadeia Simples / Carbono / Técnicas Biossensoriais / Técnicas Eletroquímicas / Nocardia Limite: Humans Idioma: En Revista: Talanta Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: DNA de Cadeia Simples / Carbono / Técnicas Biossensoriais / Técnicas Eletroquímicas / Nocardia Limite: Humans Idioma: En Revista: Talanta Ano de publicação: 2024 Tipo de documento: Article