Your browser doesn't support javascript.
loading
Quantitative Analysis of Small Intestinal Motility in 3D Cine-MRI Using Centerline-Aware Motion Estimation.
van Harten, Louis D; de Jonge, Catharina S; Struik, Femke; Stoker, Jaap; Isgum, Ivana.
Afiliação
  • van Harten LD; Department of Biomedical Engineering and Physics, Amsterdam University Medical Center, University of Amsterdam, Amsterdam, The Netherlands.
  • de Jonge CS; Informatics Institute, University of Amsterdam, Amsterdam, The Netherlands.
  • Struik F; Department of Radiology and Nuclear Medicine, Amsterdam University Medical Center, University of Amsterdam, Amsterdam, The Netherlands.
  • Stoker J; Amsterdam Gastroenterology Endocrinology Metabolism, Amsterdam, The Netherlands.
  • Isgum I; Department of Radiology and Nuclear Medicine, Amsterdam University Medical Center, University of Amsterdam, Amsterdam, The Netherlands.
J Magn Reson Imaging ; 2024 Aug 29.
Article em En | MEDLINE | ID: mdl-39207185
ABSTRACT

BACKGROUND:

Currently available tools for noninvasive motility quantification of the small intestine are limited to dynamic 2D MRI scans, which are limited in their ability to differentiate between types of intestinal motility.

PURPOSE:

To develop a method for quantification and characterization of small intestinal motility in 3D, capable of differentiating motile, non-motile and peristaltic motion patterns. STUDY TYPE Prospective.

SUBJECTS:

Fourteen healthy volunteers (127 small intestinal segments) and 10 patients with Crohn's disease (87 small intestinal segments). FIELD STRENGTH/SEQUENCE 3.0 T, 3D balanced fast field echo sequence, 1 volume per second. ASSESSMENT Using deformable image registration between subsequent volumes, the local velocity within the intestinal lumen was quantified. Average velocity and average absolute velocity along intestinal segments were used with linear classifiers to differentiate motile from non-motile intestines, as well as erratic motility from peristalsis. The mean absolute velocity of small intestinal content was compared between healthy volunteers and Crohn's disease patients, and the discriminative power of the proposed motility metrics for detecting motility and peristalsis was determined. The consensus of two observers was used as referenced standard. STATISTICAL TESTS Student's t-test to assess differences between groups; area under the receiver operating characteristic curve (AUC) to assess discriminative ability. P < 0.001 was considered significant.

RESULTS:

A significant difference in the absolute velocity of intestinal content between Crohn's patients and healthy volunteers was observed (median [IQR] 1.06 [0.61, 1.56] mm/s vs. 1.84 [1.37, 2.43] mm/s), which was consistent with manual reference annotations of motile activity. The proposed method had a strong discriminative performance for detecting non-motile intestines (AUC 0.97) and discernible peristalsis (AUC 0.81). DATA

CONCLUSION:

Analysis of 3D cine-MRI using centerline-aware motion estimation has the potential to allow noninvasive characterization of small intestinal motility and peristaltic motion in 3D. EVIDENCE LEVEL 3 TECHNICAL EFFICACY Stage 2.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Magn Reson Imaging Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Magn Reson Imaging Ano de publicação: 2024 Tipo de documento: Article